19
5201335 REV A
IQ POWER BPS-C POWER SUPPLY
NOTE
– Calibration should be performed when the system is first installed
and may be performed after the static bars have been cleaned and the system
verified as operating correctly.
4. If the system is new, perform an initial calibration. The initial calibration sets
relative nominal ion output for the system. The calibration should only be
performed on systems that are new or just cleaned and known to be in proper
working order.
During calibration the Conveyostat must be clear of material, i.e. no material is to
be flowing through the Conveyostat. If material is flowing in the Conveyostat (e.g.
the machine is in operation) the calibration may be faulty.
The system should be “on” and in the operating mode (not in start-up mode). On
units NOT connected to a Control Station: press the face label on power supply
firmly on the word “Calibrate”. This will initiate the calibration sequence and set
relative nominal ion output for the system. On units connected to a Control station,
tap on the device icon, neutralizer tab. The Device Calibrate button may be found
on page 2. Tapping on Device Calibration initiates the calibration sequence.
During calibration the system output will be cycled. At completion of calibration
the indicator lights will flicker. The indicated ion output will be high. The
calibration sequence takes less than one minute.
The calibration data is stored in non-volatile memory and used on subsequent
power-ups.
System Operation (with IQ Power Control Station)
The operation of the IQ Power BPS-C Power Supply can be controlled through
the IQ Power Control Station. In operation, a device icon appears on the Control
Station Home Page. Tapping on the device icon opens a Summary page containing
information about the BPS-C static neutralizer. More detailed information and
user-editable parameters are available through device tabs. For information on these
details see the Set Up (with IQ Power Control Station) section in this document.