The Warning state of the Dual Phase+ is indicated on the Warning pins of the
remote interface. The relay contacts change with the illumination of the Yellow
warning light on the front of the unit. It is normal for the warning condition
to be intermitted, if the warning indication is continuous servicing the connect
Conveyostat should be completed. Typically with warning light indicates that ion
generation of one or more bars is impeded by debris.
The Fault state of the Dual Phase+ is indicated on the Fault pin of the remote
interface.
The relay contacts change state with the illumination of the Red fault light on the
front of the unit. In a fault condition the red light flashes, relay contacts for fault
toggle accordingly. In this case ionization is shut down for safety, the installation
should be checked for high voltage wiring faults or other conditions that would
create an high voltage arc.
NOTE
–
Wiring to the remote interface connector should be routed clear of
the high voltage generators internal to the Dual Phase+.