Dual Phase+ Power Supply
5100636 Rev. F
Mounting and Grounding
CAUTION
– Failure to properly ground the power unit may result in electrical
shock hazard to personnel and inefficient operation of the static neutralizer.
1. Mount the power unit to the machine frame or to a convenient wall or post.
Mount the power unit to a flat surface using the mounting flanges at the base
of the power unit. Be sure to position it so that the power unit’s case is properly
grounded in order to ensure safe and efficient operation of the static neutralizer.
2. Ground the Dual Phase+ Power Supply by the following method: When
installing the AC line power wiring, use 3-conductor cable. Two conductors
will supply the line voltage. The third conductor will provide the ground
connection between the ground at the power source (junction box or panel)
and the ground post on the inner side of the wiring compartment of the power
unit’s case.
Figure 1. Dual Phase+ Enclosure