8. Maintenance
Warning:
-
When working on the equipment, the power supply must be completely disconnected.
8.1 General maintenance
- The regular cleaning of the ionization points and the (optional) filter is important for the proper
functioning of the XC.
- Inspect the filter material for contamination. If necessary, clean the filter, see 8.3.
- The air inlet and outlet can be cleaned with a soft brush or a vacuum cleaner.
- For stubborn dirt, use Veconova 10 (information at: www.eco-nova.nl).
8.2 Cleaning ionization points
- Slide the brush in the discharge grille back and forth several times.
- It is recommended to clean the ionization points every week.
8.3 Cleaning the filter
- Slide the filter out of its holder.
- Blow the filter clean and/or rinse it out with water.
- In case of heavy soiling, wash the filter with mild soap and then rinse well.
- Blot the filter with a paper towel and let it dry completely.
- Slide the filter back into the holder.
- Replace the filter when it can no longer be cleaned or when it is damaged.