Integrated Valve
Appendix F: Setting the IP Address of an IDS3000
Page 80 of 86
5760-107 Operations Manual Rev C
5. Plug one end of the Ethernet crossover cable into P1 on the circuit board. Plug the
other end into the Ethernet connector on your PC.
6. Plug in the IDS3000 and turn it on.
7. Open a Command Prompt (DOS window) on your PC; go to the folder where you
installed
setip.exe
.
8. Type
setip
, followed by a space, followed by the IDS3000 MAC address recorded in
step 4, followed by a space, followed by the IP address for the IDS3000, then press
Enter. For example, type
setip 00:06:0B:00:00:13 10.1.2.2
.
9. To verify that the IDS3000 was set to the desired address, type
ping
, followed by a
space, followed by the address. For example,
ping 10.1.2.2
. If successful, the
response will look something like this:
An unsuccessful attempt will look like this:
10. Turn off the IDS3000 and unplug it. Remove the Ethernet cable and put the cover back
on.