Priming the System
1. To prime the IDS3000 for the first time after
installation, hold the prime button and simulta-
neously depress the Power button. The pump will
automatically start, and will run for up to 20
cycles, pushing ink into the lines. The pump will
turn off when the accumulator reaches its normal
operating pressure. (If there is excessive air in
the lines, the process may need to be repeated,
as the pump will turn off automatically after 20
cycles.)
2. It will still be necessary to bleed the air from
the lines. Open the shutoff valve on the efflu-
ent bottle assembly by pushing together until
the connections snap into place; this will
allow air to flow out of the main line. As soon
as ink begins flowing into the effluent bottle,
close the shutoff valve and disconnect the
assembly. Keep a clean wipe handy to clean
up any ink drips.
3. Move the effluent bottle assembly to the first
print head in the line and connect it to the ink
exit (lower) fitting on the head. Repeat Step
2 for each print head to remove all air from
the lines.
IDS3000
Power
Prime
Effluent Bottle
Shut-Off
Valve
OPEN SHUTOFF VALVE
Summary of Contents for Diagraph IJ3000
Page 2: ......
Page 8: ...Integrated Valve Page iv of iv 5760 107 Operations Manual Rev C ...
Page 10: ...Integrated Valve Section 1 Introduction Page 2 of 86 5760 107 Operations Manual Rev C ...
Page 12: ...Integrated Valve Section 2 Safety Page 4 of 86 5760 107 Operations Manual Rev C ...
Page 22: ...Integrated Valve Section 3 System Components Page 14 of 86 5760 107 Operations Manual Rev C ...
Page 60: ...Integrated Valve Section 7 Troubleshooting Page 52 of 86 5760 107 Operations Manual Rev C ...
Page 76: ...Integrated Valve Appendix C Parts and Supplies Page 68 of 86 5760 107 Operations Manual Rev C ...