Automatic Water
System Pump
CAUTION
Not For Continuous Duty, Intermittent
Duty Only
Installation/Mounting
CAUTION
Installation Notes: To avoid the risk of fire. Be
sure that the area where pump is installed is isolated from gas,
fuel tanks, electrical wiring looms or flammable substances.
Failure to do so may cause injury or death.
1: Select pump location. Pump
must be installed in a dry,
ventilated area.
2: Connect fittings supplied
with the pump to the vessels
plumbing. Use ½” (13mm)
I.D. flexible hose (preferably
braided or reinforced) to reduce
vibration through the plumbing
system (Figure 1). Use hose
clamps on the slip on barb hose
connectors.
Important:
Install strainer pump inlet to
protect valves from debris.
3: Fasten pump to a flat surface. If mounting
vertically; install with pumphead down (Figure 2) Do not over
tighten screws to allow rubber mounts to absorb vibration.
4: Install inlet (A) and discharge (B) fittings. Firmly push slide
clips (C) forward to lock fittings in place. – Figure 3
Horizontal
Vertical
NOTE:
Do Not Submerge
Figure 2.
20381-000
QUAD PORT x
1/2" MALE QEST.
STRAIGHT
20381-002
QUAD PORT x
1/2" HOSE BARB
STRAIGHT
20381-006
QUAD PORT x
3/4" HOSE BARB
STRAIGHT
20381-007
QUAD PORT x
GARDEN HOSE
STRAIGHT
20381-008
QUAD PORT x
1/2" MALE QEST.
90 ELBOW
20381-009
QUAD PORT x
1/2" HOSE BARB
90 ELBOW
20381-010
QUAD PORT x
3/4" HOSE BARB
90 ELBOW
Exploded View
Accessories – Snap-In Port Fittings
Dimensions:
Width – 6 1/8 inches (155.58mm), Height – 4 3/4 inches (120.65mm), Length – 9 7/8 inches (250.83mm)
Model Reference
Figure 1.
2
1
4
7
Includes items 1 thru 4
9
8
6
3
5
Model
Voltage
Max Amp Draw
(Fuse/Breaker)
Flow -
GPM (lpm)
Running
Pressure
Switch Cut-off
Pressure (BAR)
42755-0092
12V dc
12A (15A)
5.0 (19)
40 (2.75)
60 (4.1)
42755-0094
24V dc
6A (10A)
5.0 (19)
40 (2.75)
60 (4.1)
Parts List
Figure 4.
Water
Tank
City Water
Inlet
Water
Heater
Check
Valve
Autofill Tank Valve,
Plumb to Tank
Pumpgard
Strainer
Do Not Plumb Autofill
to Pump Suction Line
Figure 5.
Bridge
Back of
Switch
Fuse
Figure 3.
Inlet Strainer (A)
Discharge (B)
KEY
Description
QTY
Kit no
1
Upper Housing
1
18910-4060
2
Valve Kit
1
18911-7030
3
Diaphragm Kit
1
18912-3040
4
Lower Housing Kit
1
18915-9002
5
Pressure Switch
1
18916-0060
6
Service Kit
1
18920-9043
KEY
Description
QTY
Kit no
7
Motor - 12
1
18753-5236
Motor - 24
1
18753-5237
8
Slide Clips
1
30648-1000
9
Pumphead Assembly
1
18914-6330
10
Pumpgard Strainer
1
46400-9500
30649-1000 30654-1000 30653-1000 30650-1000 30655-1000 30651-1000 30642-1000
PRECAUCIÓN
SI NO ESTÁ FAMILIARIZADO CON LAS NORMAS
ELÉCTRICAS APLICABLES, HAGA QUE UN ELECTRICISTA
CALIFICADO INSTALE LA UNIDAD.
PRECAUCIÓN
Se provee información del cableado sugerido como referencia.
Para más información, consulte las directrices de la norma
E-11 del ABYC, “Sistemas Eléctricos de CA y CC Instalados en
Embarcaciones”.
Tabla de tamaños de cables
Longitud total del cable – pies (metros)
Voltaje de
0 - 20 pies
20 - 35 pies 35 - 55 pies
la bomba
(0 - 6 m)
(6 - 9 m)
(9 - 12 m)
12 VCC
Nº14 AWG
Nº12 AWG
Nº10 AWG
(2.5 mm
2
)
(4 mm
2
)
(6 mm
2
)
24 VCC
Nº16 AWG
Nº14 AWG
Nº12 AWG
(1.5 mm
2
)
(2.5 mm
2
)
(4 mm)
PRECAUCIÓN
La carcasa del motor puede calentarse durante el
funcionamiento por períodos largos. El contacto prolongado con
la piel puede causar quemaduras.
PRECAUCIÓN
Instale un filtro en una ubicación accesible (para
inspección y limpieza) entre el tanque y la entrada de la bomba,
para proteger a la válvula contra la acumulación de desechos.
Operación
• Llene el tanque de agua
• Abra todos los grifos
• Encienda la bomba
NOTA: Espere un retardo de 10 segundos para el encendido.
• Cuando el agua esté libre de aire, cierre todos los grifos
empezando por el más cercano a la bomba (Figura 6)
Importante:
No opere la bomba más de 15 minutos seguidos.
Initial Start Up
Demand Off
Demand On
Puesta en marcha inicial
Demanda desactivada
Demanda activada
Figura 6.
ADVERTENCIA
El cableado debe cumplir las normas eléctricas aplicables e incluir
un fusible o disyuntor de tamaño apropiado. El cableado incorrecto
puede originar incendios que pueden causar lesiones o muerte.
PELIGRO DE INCENDIO
Horizontal
Vertical
NOTE: Do Not Submerge