2.5.7 Maintenance
For safe and reliable operation, it must be
ensured with regular inspection intervals that
the unit is properly serviced and kept in a per-
fect technical condition.
Example: Functioning of the rolling bearings. The
mode of operation and operating conditions largely
determine the actual service life that can be attained.
Regular checks of the bearings and there running
noise can prevent excess temperatures due to hot-
running bearings, collision of the outer magnet as-
sembly against the lantern or even defective bearing
seals. See
Section 7.2
.
If auxiliary systems (e.g. external flushing, cooling,
heating) are installed, a check must be made to see
whether monitoring facilities are required to safeguard
their operation.
2.5.8 Electric peripheral equipment
Electric peripheral equipment, e.g. pressure,
temperature and flow sensors etc. must com-
ply with the prevailing safety requirements and
explosion protection provisions.
3 Transport
and
storage
The pump or the unit must be transported
properly. It must be ensured that during
transport the pump/unit remains in the hori-
zontal position and does not slip out of the transport
suspension points.
A pump or motor can be suspended from the ring bolt
provided for this purpose.
The suspension points are not suitable for transport-
ing a complete unit, i.e. pump with base plate and
motor.
In this case, the slinging points for the ropes on the
base plate are to be used. See
Figure 1
.
The slinging ropes must not be attached to free shaft
ends or to the ring bolt of the motor.
Fig. 1
Directly after receipt of the goods, the consign-
ment must be checked for completeness and any
in-transit damage.
Damaged pumps must not be installed in the plant.
When unpacking magnetic drives as single
parts, the relevant notes in
Section 7.5.2
must be observed.
Handle goods carefully to prevent damage.
Flange covers serve as protection during transport
and must not be removed.
If the unit is not installed immediately after delivery, it
must be put into proper storage.
It should be stored in a dry, vibration-free room as at
constant a temperature as possible.
If magnetic drives are stored as single parts,
the relevant notes in
Section 7.5.2
are to be
observed.
In the case of
prolonged storage
conservation
agents on machined component surfaces and packing
with a desiccant may be necessary.
3.1 Return consignments
Pumps which have conveyed aggressive or toxic me-
dia must be well flushed and cleaned before being
returned to the manufacturer's works.
A
General Safety Certificate
on the field of applica-
tion is to be enclosed with the returned goods.
Pre-printed forms are enclosed with the installation
and operating manual.
Safety precautions and decontamination methods are
to be mentioned.