Installation and Operating Instructions
Model
ICM, ICMP
,
oil bath lubrication
9330-051-en
Revision 14
TM 6099 MPE/Wm
Page 3
Date 24/08/2011
Relevant documents
♦
Data sheet
♦
Sectional drawing pumps
♦
GA drawing
♦
Performance curves
♦
Spare parts list
♦
Operating manual motor *
♦
Operating manual coupling *
♦
Declaration of conformity for the entire unit to Ma-
chine Directive 2006/42/EC
♦
Pump to ATEX :
Declaration of conformity for the pump to Directive
94/9/EC
*
if
contained in the scope of delivery
1 Technical
Data
Manufacturer :
ITT Goulds Pumps
Millwey Rise Industrial Estate
Axminster, Devon,
EX13 5HU
UK
Tel : +44 (0)1297-639100
Fax : +44 (0)1297-630476
Designation :
Model
ICM
Magnetic Chemical Process Pump, bearing lubrica-
tion: oil bath.
Model
ICMP
Magnetic Chemical Process Pump for high pressure /
high temperature applications, with center-line
mounted casing, bearing lubrication: oil bath.
Technical specifications to ISO 15783 and
DIN
ISO
5199
Connecting dimensions to ISO 2858 / DIN EN 22858
Flange connecting dimensions:
DIN EN 1092-2, type B
(ISO 7005-2, type B) PN 16
ATEX 95 Directive 94/9/EC
Machine Directive 2006/42/EC
Housing materials :
Standard
ICM
ICMP:
Stainless steel (1.4408),
Optional
ICM ICMP
: Ductile
cast
iron/cast
steel,
Duplex, Hastelloy C, tita-
nium
Flow rates :
up
to
340 m
3
/h
(at 2900 rpm)
Delivery heads :
up to
150 m LC
(at 2900 rpm)
Housing discharge pressure :
ICM
16 bar
(max. 25 bar with 65-40-315, 50-32-315 and 80-50-315)
ICMP
25 bar
Temperature range :
- 40 °C to + 280 °C
Note: Consult the manufacturer for higher pressures
and lower or higher temperatures.
Temperature classes :
see Section
2.5.6
Admissible ambient conditions for pumps
acc. to directive 94/9/ EG (ATEX 95) :
Ambient temperature range:
- 20 °C to + 40 °C
(higher temperature after consulting the manufacturer)
Ambient pressure range:
0,8 barabs to 1,1 barabs
Sizes:
Group 1
Group 2.1
Group 2.2
40-25-160
*
100-65-160
40-25-250
*
50-32-160 125-80-160 50-32-250
65-40-160 100-65-200 65-40-250
80-50-160 125-80-200 80-50-250
40-25-200
*
125-100-200 100-65-250
50-32-200 125-80-250
65-40-200 50-32-315
*
80-50-200 65-40-315
80-50-315
*
Low-Flow sizes :
not included in ISO 2858 / DIN EN 22858
not as model ICMP
Dimensions :
See installation drawing