5.1.4 Installing the motor on base plate
Only required when the pump unit is completed at the site of instal-
lation.
If the pump is supplied without base plate, design the base plate so
that torsion and non-permitted vibrations can be safely prevented
during operation. Provide height compensation for the drive.
The pump-side coupling half is pre-fitted with a transition fit as
standard.
NOTICE!
Property damage due to installation errors!
–
Do not tilt half-couplings when sliding on.
–
Make sure that pump and motor components are not subjected
to shocks or impacts.
–
Do not shrink on half-couplings by heating.
Materials:
n
Spacer
1.
Lift motor (
manufacturer's instructions).
2.
Place motor on base plate.
3.
Bring together coupling halves. Maintain the specified gap dimension
between the coupling halves (
dimensioned drawing).
4.
Compensate the motor shaft end using suitable shims on the motor to the
height of the pump shaft end.
5.
Screw in the motor screws, do not yet tighten (
).
5.2 Preparing for installation
5.2.1 Checking the ambient conditions
1.
Ensure that the required ambient conditions exist (
pump data sheet).
2.
Ensure that no potentially explosive atmosphere exists (
ATEX additional
instructions).
5.2.2 Preparing the installation site
Ensure that the site of installation fulfils the following requirements:
n
Ensure the pump is freely accessible from all sides (
dimensioned
drawing),
n
Sufficient space for installation/removal of pipe lines and maintenance
and servicing work, in particular for installation/removal of the pump
and motor,
n
no effects due to external vibrations on the pump system (bearing
damage),
n
Frost protection,
n
Sufficient lighting.
Installation and connection
Type SLH-4G, SLHS-4G
28