141
Appendix B. Troubleshooting
79-0003-003 22 October 1999
Batteries
The batteries take much longer than three hours to charge
•
Under moderate temperatures, about 21°C (70ºF), the computers
battery takes 3 to 4 hours to completely charge. Under extremely
cold or hot temperatures, however, the battery can take up to 16
hours to fully charge.
The batteries dont last very long
•
Deep cycle discharge the battery using the Battery Maintenance
application. If your battery is new or has not been used for several
weeks, deep cycle discharging the battery over two or three
consecutive weekends may substantially increase its capacity.
•
As your battery ages, the maximum capacity that it can hold
naturally decreases, and even the best maintained batteries
eventually need to be retired. Consider replacing the battery if you
are not getting the usage you need from it.
•
You may have a defective battery. Check the battery condition with
the Battery Status application. Generally, a battery should be
replaced when it charges to less than 80 percent of capacity.
The charging light doesnt flash
•
Verify that a battery is installed in the unit.
•
This may indicate that the charging process terminated. Use the
Battery Status application to determine whether a normal or
abnormal condition caused the charging process to terminate. Select
Last Charge Termination in the More Info dialog box.
The gas gauge isnt full after charging the battery
•
This may indicate that the charging process terminated prematurely.
Use the Battery Status application to determine if some condition
caused the charging process to terminate. Select Last Charge
Termination in the More Info dialog box.
Summary of Contents for X-C 6250 Pro
Page 1: ...X C 6250 Pro User s Manual...
Page 24: ...24 X C 6250 Pro User s Manual 79 0003 003 22 October 1999...
Page 36: ...36 X C 6250 Pro User s Manual 79 0003 003 22 October 1999...
Page 46: ...46 X C 6250 Pro User s Manual 79 0003 003 22 October 1999...
Page 56: ...56 X C 6250 Pro User s Manual 79 0003 003 22 October 1999...
Page 62: ...62 X C 6250 Pro User s Manual 79 0003 003 22 October 1999...
Page 110: ...110 X C 6250 Pro User s Manual 79 0003 003 22 October 1999...
Page 124: ...124 X C 6250 Pro User s Manual 79 0003 003 22 October 1999...
Page 134: ...134 X C 6250 Pro User s Manual 79 0003 003 22 October 1999...
Page 166: ...166 X C 6250 Pro User s Manual 79 0003 003 22 October 1999...
Page 172: ...172 X C 6250 Pro User s Manual 79 0003 003 22 October 1999...
Page 173: ...Itronix Corporation P O Box 179 Spokane WA 99210 0179 www itronix com 79 0003 003...