Important
: You must twist—not wrap—the cable armor onto the pit module cable.
Wrapping the cable armor can cause the stainless steel jacket to warp.
Warning
: You must begin twisting the cable armor over portion of the cable
protected by the electrical tape. If you do not begin to twist the cable armor
over the protected portion of the pit module cable, a cut cable could cause an
pit module/register communication failure.
5. Continue to twist the cable armor onto the pit module cable until the cable armor covers
the entire cable.
Warning
: You must continue to twist the cable armor onto the cable protected
by the electrical tape. If you do not twist the cable armor over the protected
portion of the cable, you could initiate a cut cable and cause and pit module/
register communication failure.
6. Remove any leftover materials from the customer premises. Discard or recycle leftover
materials.