• If the rod is the correct depth but remains loose in the soil, replace the rod with a
longer version.
6. The top of the rod must be 3-1/2 inches below the bottom of the lid (see the illustration in
Step 10). Place the Riva module on the rod. Completely insert the rod into the pit
module's rod mount hole. Do not force the pit module onto the rod. If the pit module does
not slide freely on the rod, remove the pit module and examine the pit module rod hole
and rod for burrs or obstructions.
7. You may secure the pit module to the rod with a self-drilling screw through the hole in the
top of the pit module's rod mount cavity.
8. Connect the register (black connector-1), optional remote antenna (red connector-2) and
optional telemetry device (blue connector-3) into the appropriate connection.
9. Turn the connector locking ring to secure the connection.
Caution
: Turn only the locking ring. Turning the entire connector could
damage the connector pins.
10. Installation is complete when the pit module is perpendicular to the underside of the lid.
The pit module must not contact the pit structure or lid.
Installing the OpenWay Riva Water Pit Module
OpenWay Riva Pit Water Module Installation Guide TDC-1666-000
19
Proprietary and Confidential