Caution
: Do not over-tighten the mounting screws. Over-tightening the
mounting screws may break the pit module mounting tabs.
7. Start a screw into the pilot hole. Using the top hole of the pit module, set the pit module
over the screw head and slide it down so the screw is now at the top of the notch.
Carefully tighten the screw until snug. Over-tightening the mounting screw could damage
the pit module housing.
Note
: If the mounting location requires a screw anchor, mark the location of the bottom
anchor and remove the pit module. Drill the required mounting hole, insert the anchor,
and re-attach the pit module.
8. Holding the pit module in the upright position, drill the second pilot hole. Use the bottom
mounting hole as a template.
Caution
: Any pit module position other than upright may negatively affect
radio performance and battery life.
9. Screw the bottom screw into the pilot hole until snug. Do not over-tighten the mounting
screw.
Wall mounting the OpenWay Riva pit module is complete.
Optional Riva Leak Sensor installation
This section describes installation of the OpenWay Riva Leak Sensor in a OpenWay Riva
Water system.
The water module stores 20 days of Riva Leak Sensor data. On the 21st day, the module
begins to write over stored data in a first in, first out manner.
Installing the OpenWay Riva Water Pit Module
OpenWay Riva Pit Water Module Installation Guide TDC-1666-000
22