Module wire color
Red
Black
White
Register manufacturer Register screw color designator
RG3 Tomahawk
Green
Black
Green
Sensus PMM
Red
Black
Bare
Note
: *For the Badger RTR connection, Itron recommends terminating the unconnected
wire with a gel-cap connector to protect the bare wire end. (For more information about
installing gel-cap connectors, see Using Gel Cap Connectors.
Verifying pit module operation
Use one of the following handheld computers to verify consumption:
• FC200SR handheld computer (Itron part number FC2-0005-004 or FC2-0006-004)
• FC300 SR handheld computer
• 900 MHz Belt Clip Radio
• Itron Mobile Radio
Note
:
• Each handheld radio requires special setup and configuration parameters to successfully
read and program the pit module. Refer to the respective meter reading application for
specific instructions.
• When comparing the actual register value to that reported by the pit module, please keep
in mind the water module's consumption value is updated once an hour when it is in run
mode.
Caution
: Verifying the OpenWay Riva Water Pit Module operation requires an
FC200SR handheld computer, FC300SR handheld computer, 900 MHz Belt Clip
Radio, or Itron Mobile Radio running FDM v4.0 or higher. Legacy Itron handheld
programming devices cannot read the pit modules.
Initializing, Connecting, and Programming the OpenWay Riva Water Pit Module
OpenWay Riva Pit Water Module Installation Guide TDC-1666-000
12
Proprietary and Confidential