Specification
Specification value
■
20LT
■
30LT
■
1A/Sprague standard
■
1-1/4", 1" Pittsburgh
■
ISO G 1-1/4"
Meter MAOP
5 PSIG (35 kPa)
Valve
Actuated swing valve, maximum 0.035 CFH (1 L/H) leakage rate
LCD displayed units
CCF (100 x cubic foot) or cubic meter
LCD resolution
00000.001 CCF (0.1 CF) or 00000.001 m
3
Case
Aluminum case with ASA 49 gray powder coat finish
Weight
4.5 lbs (2.0 kg)
Gas type
■
Natural gas Type H, E, L (per EN 437)
■
Reference gases G20, G21, G23, G25, G26, G27
Component materials
■
UMU (ultrasonic measuring unit): polybutylene terephthalate (PBT) and
polycarbonate (PC)
■
Valve plastics: PBT
■
Inlet and outlet tubes: polyoxymenthylene (POM)
Intrinsically safe
For use in Class I, Division 1, Group D hazardous locations.
Temp Code T1 -40°C ≤ Ta ≤ +70°C
IECEx UL 18.0144X Ex ia IIA T1 Ga
Regulatory
■
FCC:
Part 15.247, Part 15.249 (programming)
■
FCC ID:
EWQINTELISG
■
Innovation, Science, and Economic Development Canada (ISED):
RSS-247 and
RSS-210 (programming)
■
IC ID:
864D-INTELISG
■
Measurement Canada:
Pending
Operational
All Intelis Gas Meters operate without the need for an FCC or ISED license.
■
Frequency:
902-928 MHz ISM band
■
Program frequency:
908-923.8 MHz
Australia
■
ACMA AS/NZS 4268
■
Frequency:
915-928 MHz ISM band
■
Program frequency:
916-926.8 MHz
Operating temperature ratings
■
Measurement:
-30° F (-34° C) to +131° F (55° C)
Table 1
Intelis Gas Meter specifications (continued)
08 July 2020
815-0154-00 REV 000
Itron, Inc. Page 12 of 66
Intelis Gas Meter Proving and Setup Guide
2 Overview