5
Original notice - T1.10
IB-P03
T
echnical
documenTaTion
3.2 - d
imensions
3.3 - g
eneral
sPecificaTions
SPECIFICA
TIONS
Power Supply
Safety Extra Low Voltage 24VDC ± 10% - ripple < 10%
A stabilised power supply is recommended
Absorbed current without motorized roller
0.5A
Start current limitation
4.0A
Motor start time after signal
10.8ms
Protection index (IP)
IP54
Environment
Temperature range 0 / +40 °C (No freezing)
Relative humidity < 90% condensation-free (avoid thermal shocks)
Neither corrosive nor explosive atmosphere
Vibrations <1 G
Indoor use
UL certification
UL approval version available. Please contact us.