29
Original notice - T1.10
IB-P03
T
echnical
documenTaTion
9.3 - w
hen
The
neTwork
is
configured
only
wiTh
iB-P03
circuiT
Board
Set each IB-P03 circuit board as a master, and download ladder logic onto each of them. Each IB-P03 circuit
board controls its own zone. The control can be performed without connecting the PC or PLC.
IB-P03 (Master)
IB-P03 (Master)
IB-P03 (Master)
IB-P03 (Master)
With ladder
With ladder
With ladder
With ladder
Communication between boards
(sensor information, etc...)
9.4 - w
hen
one
iB-P03
circuiT
Board
conTrols
mulTiPle
connecTed
iB-P03
circuiT
Boards
Download ladder logic onto the master IB-P03 circuit board. Set other IB-P03 circuit boards as slaves. The
master IB-P03 circuit board controls its own zone and the zones of the slaves. Up to seven slave IB-P03 circuit
boards can be controlled by one master IB-P03 circuit board.
IB-P03 (Slave)
IB-P03 (Slave)
IB-P03 (Slave)
IB-P03 (Slave)
Ladder N/A
Ladder N/A
Ladder N/A
Ladder N/A
Communication between boards
(sensor information, etc...)
IB-P03 (Master)
Communication
between boards
(motor RUN instruction)
With ladder
Up to 7 IB-P03 circuit boards