7
Original notice - T1.10
IB-P03
T
echnical
documenTaTion
3.6 - c
onnecTors
for
iB
CN201 : Motor cable
M8 5 pin female connector
CN305 : Sensor cable
M8 4 pin female connector
CN402 : Communication cable
M12 4 pin D-coded male connector
CN101 : Motor cable
M8 5 pin female connector
CN304 : Sensor cable
M8 4 pin female connector
CN401 : Communication cable
M12 4 pin D-coded female connector
Control Power
DRV Power
N°
For
1
+24V
2
0V
N°
For
1
+24V
2
0V
Use As-i cable for power cable.
Use As-i cable for power cable.
N°
For
1
+24V
2
Sensor alarm
3
GND
4
Sensor signal
• Input for sensor and sensor alarm is fixed to PNP input.
• The setting for “Dark ON” or “Light ON” can be switched with iCEP or PLC.
- With iCEP: Refer to «iCEP» user manual.
- With PLC: Refer to «Connection with PROFINET capable PLC» user
manual - Paragraph 5 «How to change parameters».
• Ensure that sensor current consumption doesn’t exceed 1.1 A (Sensor A +
Sensor B)
Control Power : As-i pin
DRV Power : As-i pin
Sensor cable : M8 4 pin connector
Connection of 2 sensors is possible by using M8 4pins to 2 x
M8 3 pins adaptors such as SAI Y-4S M8-M8 (Weidmüller).
So, Alarm signal will be the second sensor signal.
1
4
2
3
1
4
3
1
4
3
S1
S2
Circuit diagram