background image

 ITOH DENKI CO.,LTD.

1

2

2

2

) ~ (

3

3

3

) ~ (

4

4

4

) ~ (

6

4

) ~ (

6

7

7

7

8

8

) ~ (

9

9

1 0

) ~ (

11

1 2

1 3

1 3

1 3

  1 Safety Instructions
  2 Power  
  3 Before Operating the Product

  

3-1  Mounting 

  

3-2  Wiring 

  

3-3  Direction Setting  

  4 Functions 
  5 Operation Instructions 

  

5-1  Speed Variation

   

5-1-1  Internal Speed Variation

   

5-1-2  External Speed Variation

  

5-2  Direction Setting 

  

5-3  Acceleration and Deceleration

  6  Error Signal Output

  

  7  Motor Pulse Signal Output 
  8  Error status, Reset, History

  

8-1  Error History 

  

8-2  Indication of Error Occurrence Frequency 

  9  Troubleshooting
10  Dimensions 
11  Product specifications
12

  

Applicable standards

 -UL

) 

 

Standard Accessories

INDEX

 Power connector (CN 1) 

 Control connector (CN 2)

 Mounting screws and nuts

      Screw M4 x 15 
      Nut M4   

1pce
1pce

2pcs
2pcs

Power connector 

(CN 1)

Control connector

 (CN 2)

No.490

Brushless DC Motor Driver

CB-016

N6

〔B

N6

P6

BP6

〕】

User Manual

PM486FE

PM500FE

PM486FP

PM500FP

PM570FE

PM605FE

PMT42FE

CB-016N6

/

LT-UL

Thank you for purchasing a Itoh Denki CB-016 series 
motor driver. Please read this manual before operating 
the product, and keep this manual readily accessible for 
reference.

Applicable MDR models

Motor driver model

N : For standard motor, 

      NPN signal input and output
P : For standard motor, 

      PNP signal input and output
BN : For built-in brake motor, 

        NPN signal input and output
BP : For built-in brake motor, 

        PNP signal input and output

LT : Low Temp

UL : UL recognized

1

Maximum Surrounding Air Temperature

 

40

.

Switch off the power, when removing from conveyor, wiring or maintenance is 
done, otherwise you have a risk of electrical shock or injury.
Respect the electrical regulations of the site or the equipment, where the 
product in installed. (Labour safety and sanitary regulations, electrical 
equipment technical standard, etc)
Operate the motor driver within its intended design and specifications to 
avoid electrical shock, injury, fire, or damage to the equipment.
Do not disassemble, repair nor modify the product (for which we do not 
warrant) It might cause electrical shock, injury or fire.
Separately set the circuitry to monitor the important input and/or output signal 
status, which might cause accident, because the signal may stay ON or OFF 
in case of the CB-016 driver card failure.
Be sure to shut off the power before inserting or removing any connector. Do 
not wire connector left in the CB-016 driver card. 
Do not drop, give external impact nor pressure to the CB-016 driver card.  If 
that happens, do not reuse it.
Make sure all the connecters are properly engaged with wiring cables. 
Make sure the conveyor frame and control box where the CB-016 driver card 
is mounted are grounded.
Do not switch on or off the relay or contactor in close proximity to power or 
signal lines, or the CB-016 driver card as the generated noise could cause 
malfunction.
Be sure to inject power or input signal for 15 milli-seconds or over to ensure 
the proper reaction. 
Use the MDR with built-in brake option (BR) along with CB-016 driver card 

〔B

N6

〕〔BP

6

 if holding effect is needed.

Do not pull by force during operation. It causes the CB-016 driver card to 
malfanction.
Do not force the MDR to turn. It may cause of damage to the driver card or 
shorten its life cycle.

1  Safety Instructions

● 

Connenctor may harden with low temperature. Do not insert and pull it by 
force.
Mount this product to the place where MDR can be properly connected 
without cable loose, extreme bend or pull, or move.
MDR speed may not reach immediately to the set speed if it is left long hours 
in 0 

 or below. In addition, the starting current may get larger to activate 

thermister, or under voltage error may be resulted. Therefore , warm up 
operation is recommended before formal use.
Be careful for condensation or freeze in case the product is used in varying 
temperature particularly between below and above 0

. If condensation is 

generated, do not use the product until it is completely removed. Use of the 
product having condensation may result in malfunction or electrical accident.

<Described below are the precautions for using this product at freezing 
temperature along with MDR having LT option:>

Warning & Caution

Possible danger of light or medium injury, or only a 
material damage.

Warning

Incorrect handling may lead to death or serious injury, 
indicating potential danger.

Shown below are the caution items for using the product safely and avoiding 
danger and damage to the user.
Caution items can be classified into danger, warning and caution as described 
below.

Caution

Caution

Summary of Contents for CB-016 series

Page 1: ...he signal may stay ON or OFF in case of the CB 016 driver card failure Be sure to shut off the power before inserting or removing any connector Do not wire connector left in the CB 016 driver card Do...

Page 2: ...arks See section 5 3 Dip Switch SW1 Min Default Acceleration from RUN signal 0 sec 2 Deceleration from STOP signal 0 sec 2 5 sec 2 5 sec Min Min Potentiometer VR Model Model nomenclature To the CCW en...

Page 3: ...R shafts are adequately secured with the supplied brackets or accessories Each connector on the driver card is adequately wired and inserted Operating and environmental conditions are respected Power...

Page 4: ...Nominal Speed m min Internal speed variation input Analog voltage Speed deviation 3 1 2 3 3 3 3 3 3 5 2 Direction Setting 5 3 Acceleration and Deceleration Reverse direction by external DIR signal ca...

Page 5: ...ect signal RUN STOP RUN order to CN2 1 Inject signal RUN STOP RUN order to CN2 1 Restarts automatically in a minute After thermister recovery inject signal ON OFF ON or OFF ON OFF order to CN2 2 After...

Page 6: ...thermister error thermister error under voltage error under voltage error under voltage error first time second time 3 times thermister error under voltage error thermister error first time second ti...

Page 7: ...ww itohdenki com Asia Oceania Itoh Denki Asia Limited Phone 852 2427 2576 Fax 852 2427 2203 China Itoh Denki Shanghai Company Limited Phone 86 21 6341 0181 Fax 86 21 6341 0180 www itohdenki com cn 4 6...

Reviews: