193.0

54.2

15.2

189.4

53.2

14.9

186.9

52.5

14.7

178.0

50.0

14.0

169.1

47.5

13.3

160.2

45.0

12.6

142.4

40.0

11.2

133.5

37.5

10.5

124.6

35.0

9.8

115.7

32.5

9.1

106.8

30.0

8.4

97.9

27.5

7.7

89.0

25.0

7.0

80.1

22.5

6.3

71.2

20.0

5.6

62.3

17.5

4.9

53.4

15.0

4.2

44.5

12.5

3.5

35.6

10.0

2.8

26.7

7.5

2.1

226.3

63.6

17.9

222.1

62.4

17.5

219.2

61.6

17.3

208.7

58.6

16.5

198.3

55.7

15.6

187.9

52.8

14.8

167.0

46.9

13.2

156.5

44.0

12.4

146.1

41.0

11.5

135.7

38.1

10.7

125.2

35.2

9.9

114.8

32.2

9.1

104.3

29.3

8.2

93.9

26.4

7.4

83.5

23.5

6.6

73.1

20.5

5.8

62.6

17.6

4.9

52.2

14.7

4.1

41.8

11.7

3.3

31.3

8.8

2.5

251.7

55.4

14.7

251.7

55.4

14.7

251.7

55.4

14.7

246.9

54.3

14.4

234.5

51.6

13.7

222.2

48.9

13.0

197.5

43.4

11.5

185.1

40.7

10.8

172.8

38.0

10.1

160.4

35.3

9.4

148.1

32.6

8.6

135.7

29.9

7.9

123.4

27.1

7.2

111.1

24.4

6.5

98.8

21.7

5.8

86.4

19.0

5.0

74.1

16.3

4.3

61.7

13.6

3.6

49.4

10.9

2.9

37.0

8.1

2.2

4

5

PM486FE

SW1-5

9.6〜9.9

9.1〜9.4

8.6〜8.9

8.1〜8.4

7.6〜7.9

7.1〜7.4

6.6〜6.9

6.1〜6.4

5.6〜5.9

5.1〜5.4

4.6〜4.9

4.1〜4.4

3.6〜3.9

3.1〜3.4

2.6〜2.9

2.1〜2.4

1.6〜1.9

1.1〜1.4

0.6〜0.9

0.1〜0.4

SW 5

210

60

17

MDR Nominal Speed (m/min) 

PM486FS/PM486FP

PM570FE

Internal speed variation

 input

Analog voltage

Speed dev/-3%

*1

*2

*3

*1  

Consult local ITOH DENKI representative in case you use MDR with 

         nominal 

speed not in the above table.

*2  

It is not available for Low temperature applications(LT)

*3  

It is not available at temperatures of -30 to 

0

 degrees or less for LT.

  

9.6〜9.9

9.1〜9.4

8.6〜8.9

8.1〜8.4

7.6〜7.9

7.1〜7.4

6.6〜6.9

6.1〜6.4

5.6〜5.9

5.1〜5.4

4.6〜4.9

4.1〜4.4

3.6〜3.9

3.1〜3.4

2.6〜2.9

2.1〜2.4

1.6〜1.9

1.1〜1.4

0.6〜0.9

0.1〜0.4

210

60

17

9.6〜9.9

9.1〜9.4

8.6〜8.9

8.1〜8.4

7.6〜7.9

7.1〜7.4

6.6〜6.9

6.1〜6.4

5.6〜5.9

5.1〜5.4

4.6〜4.9

4.1〜4.4

3.6〜3.9

3.1〜3.4

2.6〜2.9

2.1〜2.4

1.6〜1.9

1.1〜1.4

0.6〜0.9

0.1〜0.4

255

55

15

O N

O F F

O N

O F F

O N

O F F

*3

*3

*3

*3

*3

SW1-5

SW 5

MDR Nominal Speed (m/min) 

Internal speed variation

 input

Analog voltage

Speed dev/-3%

*1

*2

*3

*3

*3

*3

*3

*3

SW1-5

SW 5

MDR Nominal Speed (m/min) 

Internal speed variation

 input

Analog voltage

Speed dev/-3%

*1

*2

*3

*3

*3

*3

*3

*3

5-1  Speed Variation

5  Operation Instructions

MDR is adequately installed  in compliance with the manual.

MDR shafts are adequately secured with the supplied brackets or accessories.

Each connector on the driver card is adequately wired and inserted

.

Operating and environmental conditions are respected.

Power supply has sufficient capacity (stable 24VDC, 5A or over) so as not to 

 

be affected by varying load.

The protector for the power supply should not react with peak current 20A 

1 milli-second or less.

Supply 24VDC to the driver card, and the LED 1 (green)
 illuminates.
Close the contact of CN2-1 , and the MDR starts 
running.

 * 

0V should be common to the power voltage.

 * 

3mA current is drawn to CN2-1.

 * 

Wait 1 second after the driver card is powered before 

    running MDR.

Open the contact of CN2-1 , and the MDR stops. 

 * 

MDR run/stop should be manipulated only by CN2-1 

   and 0V, not by the 24VDC power to the driver card.

To vary the motor speed, follow the section 5-1.

To reverse the motor, follow the section 5-2.

To accelerate or decelerate the motor, follow the section 5-3. 

5-1-1  Internal Speed variation 

 ①

Set the SW1-2 OFF to effect the internal speed variation.

 ②

With the combination of SW1-5 and Rotary Switch SW5, speed can be varied in 20 

       steps. 

Speed of the MDR can be varied either internally by integral dip switch or externally by 
analog voltage input.

5-1-2  External Speed Variation 

 ①

 Set the SW1-2 ON to effect the external speed variation.

 ②

 Inject and vary the analog voltage between 0 and 10V to CN2-3 to vary the motor 

        speed in 20 steps. 

  * 

Max 2mA current is consumed at CN2-3. 

  * 

The analog voltage input should not exceed 10V.  Its 0V should be common to 

            the Power voltage.

See section 5-1
See section 5-2
See section 5

See section 6

2
1

0V
24VDC

Power Connector (CN 1) 

Rotary Switch (SW 5)

10 index speed setting 

5
4

Error signal output

3
2

External speed variation
Motor turning direction

1

Function

See section 7

Motor pulse signal ooutput

Motor Run/Stop 

Control Connector (CN 2)

1
2

Powered and functions normally

Indicates type of error

Indicates number of error occurrence form 

thermister reaction, motor stall or under voltage

Green

Remarks

Remarks

Status 

Color

Red

Orange

3

LEDs 

See section 8

See section 9

Ensure the following before operating the product

Model

Example

PM486FE-60-400-D-024

Nominal Speed

Range of speed variation differs according to the MDR model.  Check the nominal 

    speed of the model from the circular label put on its end housing. 

V-IN

RUN

DIR

123

RUN

V-IN

RUN

DIR

123

STOP

Summary of Contents for CB-016 series

Page 1: ...he signal may stay ON or OFF in case of the CB 016 driver card failure Be sure to shut off the power before inserting or removing any connector Do not wire connector left in the CB 016 driver card Do...

Page 2: ...arks See section 5 3 Dip Switch SW1 Min Default Acceleration from RUN signal 0 sec 2 Deceleration from STOP signal 0 sec 2 5 sec 2 5 sec Min Min Potentiometer VR Model Model nomenclature To the CCW en...

Page 3: ...R shafts are adequately secured with the supplied brackets or accessories Each connector on the driver card is adequately wired and inserted Operating and environmental conditions are respected Power...

Page 4: ...Nominal Speed m min Internal speed variation input Analog voltage Speed deviation 3 1 2 3 3 3 3 3 3 5 2 Direction Setting 5 3 Acceleration and Deceleration Reverse direction by external DIR signal ca...

Page 5: ...ect signal RUN STOP RUN order to CN2 1 Inject signal RUN STOP RUN order to CN2 1 Restarts automatically in a minute After thermister recovery inject signal ON OFF ON or OFF ON OFF order to CN2 2 After...

Page 6: ...thermister error thermister error under voltage error under voltage error under voltage error first time second time 3 times thermister error under voltage error thermister error first time second ti...

Page 7: ...ww itohdenki com Asia Oceania Itoh Denki Asia Limited Phone 852 2427 2576 Fax 852 2427 2203 China Itoh Denki Shanghai Company Limited Phone 86 21 6341 0181 Fax 86 21 6341 0180 www itohdenki com cn 4 6...

Reviews: