23
ä Attention
!
Always mount the condensation drain with the rubber sleeve. The
rubber sleeve ensures a watertight seal. The condensation hose
may not be glued.
Mounting with knee
pad.
The condensate drain (with dry siphon) can be connected either
right or left-handed. The condensate drain can be loosened and
tightened by hand and converted as required. In addition, the
flexible hose can be pulled out so that the drain can be connected
well outside the unit.
a) Mount the condensation drain to the left or right as required.
Assembly with Y-piece. It is also possible to connect the boiler to the
vertical piece, for example.
3.6. Connecting electrically
b) Pull out the flexible hose to the desired length and
direction.
The appliance is equipped with an earthed plug. The wired
three-position switch cannot be connected to this model.
Operation takes place via wireless control switches and/or
sensors.
Connect the ventilation unit with the earthed plug to a wall socket.
c) Connect the flexible hose with the rubber sleeve to the
condensation drain connection that leads to the
sewer.
When the ventilation unit is placed on the ground, the
condensation drain can be connected to the sewer in the following
ways:
ä Attention
!
The condensation hose must not have any sharp bends!
MAX 70 mm
ä
Warning!
Never connect the ventilation unit with an extension
cord!
MAX 70 mm
ä
Warning!
Never connect the ventilation unit with a damaged
power cable!
ä Attention
!
The distance between the underside of the appliance and the
condensation drain must
never
exceed 70 mm (lower may be).