11
2.5. Product card information
Itho Daalderop
HRU
Description
Symbol
Unit
400
Specific energy consumption class
—
—
A+
Specific energy consumption, under moderate
climate conditions
SEC
kWh/(
m2
.a)
-44
Specific energy consumption, under warm
climate conditions
SEC
kWh/(
m2
.a)
-19
Specific energy consumption, under cold
climate conditions
SEC
kWh/(
m2
.a)
-86
Type of ventilation unit
VE
—
Residential ventilation unit (RVE)
Two-way ventilation unit (TVE)
Type of drive
X
—
Variable speed
Type of heat recovery system
HRS
—
Recuperative
Thermal efficiency of heat recovery
ƞt
%
88
Maximum flow rate
qmax
m3/h
400
Electrical input power of the
fan drive, at maximum flow rate
Pmax
W
138
Sound power level
LWA
dB
53
Reference flow rate
qref
m3/s
0,08
Reference pressure difference
ΔPref
Pa
50
Specific input power
SPI
W/(
m3/h
)
0,2
Ventilation control
—
—
Central needs-driven
regulation
Control factor
CTRL
-
0,85
Declared maximum percentages for internal
leakage for two-way ventilation units
—
%
1
Declared maximum percentages for external
leakage for two-way ventilation units
—
%
1
Replace warning filter
—
—
On Electronics compartment
Via external controls
Instructions for pre-assembly/disassembly
—
—
www.ithodaalderop.nl
Annual electricity consumption
AEC
kWh
2
Annual heating savings, under temperate
climate conditions
AHS
kWh
46
Annual heating savings, under warm
climate conditions
AHS
kWh
21
Heating saved annually, under cold conditions
climate conditions
AHS
kWh
90