11
78
□80
□80 10
78
□80
□80 10
a
b
c
d
e
a
b
c
d
e
a: Hexagon Socket Head Cap Screw M6x50, T
T
= 13 Nm
b: Hexagon Socket Head Cap Screw M5x12, T
T
= 10 Nm
c: Hexagon Socket Head Cap Screw M6x16, T
T
= 13 Nm
d: Hexagon Socket Head Cap Screw M4x18, T
T
= 6 Nm
e: Centre ring D32/D48
Drive Set KRF 8 ZR AP/WP 60 – 0.0.673.31
a: Hexagon Socket Head Cap Screw M6x50, T
T
= 13 Nm
b: Hexagon Socket Head Cap Screw M6x12, T
T
= 13 Nm
c: Hexagon Socket Head Cap Screw M6x16, T
T
= 13 Nm
d: Hexagon Socket Head Cap Screw M5x20, T
T
= 10 Nm
e: Centre ring D32/D48
Drive Set KRF 8 ZR AP/WP 80 – 0.0.673.32
Maintenance
Limit-Switch Holder KRF 8
▪
The Limit-Switch Holder is prepared for fastening to the lower side grooves
of Profile 8 80x40 KRF.
▪
Optimised for Proximity Switch 8
Proximity Switch 8 1NO, 0.3.001.30 (normally open)
Proximity Switch 8 1NC, 0.0.600.05 (normally closed)
Limit-Switch Holder KRF 8 can also be used for position detection on
other item linear slides.
▪
Recommended oil: Track Oil for Linear Slides (Klüber Oil 4 UH1-460),
0.0.612.75
▪
Auxiliary tool: Pressol oil can KLE-LR, 0.0.612.74
▪
The felt pieces are supplied in ready-oiled condition.
▪
Grease containing solid particles (e.g. graphite and MoS2 - additives) must
not
be used!
▪
The maintenance openings (page 6) are located on both sides of the preas-
sembled carriage.
▪
All 4 End Cap and Lubricating Systems are re-oiled through the maintenance
openings.
▪
Minimum stroke, full lubrication: H
min
= 100 mm.
▪
Maintenance interval: every 6 months or every 2500 km.
▪
Fill quantity: approx. 1 ml per End Cap and Lubricating System and mainte-
nance interval. (1 ml is equivalent to one pump actuation of the Pressol oil can)