Quick
Start
Copyright ©ITECH Electronic Co., Ltd.
11
Yes => 3
No => Please check the
Power
key to start power and check whether the
exception is removed.
3. Check whether set power voltage of electronic load is larger than the power
supply voltage. If set power voltage is 220 V and the supply voltage is 110 V,
the electronic load cannot start.
4.
Check whether the fuse of electronic fuse is burned out.
If yes, change fuse. Detailed steps:
1
)
Pull out power line and take out the fuse box at power line jack with a small
screw driver.
As shown below.
2
)
If the fuse is fused, please change fuse of same specification based on
machine model. See the table blow for matching information of fuse and
machine model.
Product
Fuse specification(220VAC) Fuse specification(110VAC)
IT8912E
2.5AT
1.25AT
3
)
After replacement, install the fuse box back to original position, as shown
below.