14
3
rd
byte
Command
(
38H/39H
)
From 4
th
byte to 7
th
byte
Setting value of resistance A (Lower bytes are in the front location, higher bytes
are in the later location)
From 8
th
byte to 9
th
byte.
Time value of timer A (Lower bytes are in the front location, higher bytes are in
the later location) (1 represents 0.1mS)
From 10
th
byte to 13
th
byte Setting value of resistance B (Lower bytes are in the front location, higher bytes
are in the later location)
From 14
th
byte to 15
th
byte Time value of timer B (Lower bytes are in the front location, higher bytes are in
the later location) (1 represents 0.1mS)
16
th
byte
Transition operation mode (0 is CONTINUES,1 is PULSE,2 is TOGGLED)
17
th
byte to 25
th
byte
System reserve
26
th
byte
Sum code
15
.
Set /Read the list operation mode (CC)
(
3AH/3BH
)
1
st
byte
Start bit ( AAH )
2
nd
byte
Address (0
—31,0XFF)
3
rd
byte
Command
(
3AH/3BH
)
4
th
byte
LIST operation mode
(
0 is CC mode
)
From 5
th
to 25 byte
System reserve
26
th
byte
Sum code
16. Set / Read the list repeat mode. (3CH/3DH)
1
st
byte
Start bit ( AAH )
2
nd
byte
Address (0
—31,0XFF)
3
rd
byte
Command
(
3CH/3DH
)
4
th
byte
LIST repeat operation mode(0 is ONCE, 1 is REPEAT,65535 represents no limit)
From 5
th
to 25
th
byte
System reserve
26
th
byte
Sum code
17. Set / Read list step counts. (3EH/3FH)
1
st
byte
Start bit ( AAH )
2
nd
byte
Address (0
—31,0XFF)
3
rd
byte
Command
(
3EH/3FH
)
From 4
th
byte to 5
th
byte
LIST steps count
From 6
th
to 25
th
byte
System reserve
26
th
byte
Sum code
18. Set
/ Read one of the step’s current and time values. (40H/41H)
1
st
byte
Start bit ( AAH )