![background image](http://html1.mh-extra.com/html/itech/it8500plus-series/it8500plus-series_manual_2095282017.webp)
17
1
st
byte
Start bit ( AAH )
2
nd
byte
Address (0
—31,0XFF)
3
rd
byte
Command
(
5BH/5CH
)
4
th
byte
Storing area
From 5
th
to 25
th
byte
System reserve
26
th
byte
Sum code
28. Selecting / Getting FIXED/SHORT/TRAN/LIST/ BATTERY function mode.
(5DH/5EH)
1
st
byte
Start bit ( AAH )
2
nd
byte
Address (0
—31,0XFF)
3
rd
byte
Command
(
5DH/5EH
)
4
th
byte
Work mode (0:FIXED,1:SHORT, 2:TRANSITION,3:LIST,4: BATTERY)
From 5
th
to 25
th
byte
System reserve
26
th
byte
Sum code
29. Read input voltage, current, power and relative state. (5FH)
1
st
byte
Start bit ( AAH )
2
nd
byte
Address (0
—31,0XFF)
3
rd
byte
Command
(
5FH
)
From 4
th
to 7
th
byte
Actual input voltage value (Lower bytes are in the front location, higher bytes are
in the later location)
From 8
th
to 11
th
byte
Actual input current value (Lower bytes are in the front location, higher bytes are
in the later location)
From 12
th
to 15
th
byte
Actual input power value (Lower bytes are in the front location, higher bytes are
in the later location)
16
th
byte
Operation state register
From 17
th
to 18
th
byte
Demand state register
From 19
th
to 25
th
byte
System reserve
26
th
byte
Sum code
Operation status register
7
6
5
4
3
2
1
0
NO USE
LOT
SENSE
LOCAL
OUT
REM
WTG
CAL
FOR
LOAD
ON
timer
status
Remote
sense
mode
LOCAL
button
state(0 is
disabled,1
is
enabled)
Load
input
state
remote
control
mode
Waitting
for a
trigger
signal
Load is in
calibration
mode
Enquire status register