![background image](http://html1.mh-extra.com/html/itech/it8500plus-series/it8500plus-series_manual_2095282016.webp)
16
3
rd
byte
Command
(
54H
)
4
th
byte
New communication address (0~31)
From 5
th
to 25
th
byte
System reserve
26
th
byte
Sum code
23. Enable/Disable LOCAL control mode. (55H)
1
st
byte
Start bit ( AAH )
2
nd
byte
Address (0
—31)
3
rd
byte
Command
(
55H
)
4
th
byte
State of LOCAL button(0:disable,1:enable
“)
From 5
th
to 25
th
byte
System reserve
26
th
byte
Sum code
24. Enable / Disable remote sense mode. (56H)
Enquire the state of remote sense mode. (57H)
1
st
byte
Start bit ( AAH )
2
nd
byte
Address (0
—31,0XFF)
3
rd
byte
Command
(
56H/57H
)
4
th
byte
Remote mode state (0:OFF,1:ON)
5
th
to 25
th
byte
System reserve
26
th
byte
Sum code
25. Set / Enquire trigger source. (58H/59H)
1
st
byte
Start bit ( AAH )
2
nd
byte
Address (0
—31,0XFF)
3
rd
byte
Command
(
58H/59H
)
4
th
byte
Trigger mode
(0:Manual,1: External,2:Bus,3:Hold)
From 5
th
to 25
th
byte
System reserve
26
th
byte
Sum code
26. Send a trigger signal to trigging the electronic load. (5AH)
1
st
byte
Start bit ( AAH )
2
nd
byte
Address (0
—31,0XFF)
3
rd
byte
Command
(
5AH
)
From 4
th
to 25
th
byte
System reserve
26
th
byte
Sum code
27. Sav
ing / Recall user’s setting value in appointed memory area for recall.
(5BH/5CH)