The following safety precautions must be observed during all phases of operation
of this instrument. Failure to comply with these precautions or specific warnings
elsewhere in this manual will constitute a default under safety standards of design,
manufacture and intended use of the instrument. ITECH assumes no liability for
the customer’s failure to comply with these precautions.
Do not use the instrument if it is damaged. Before operation, check the casing
to see whether it cracks. Do not operate the instrument in the presence of
inflammable gasses, vapors or dusts.
The power supply is provided with a three-core power line during delivery and
should be connected to a three-core junction box. Before operation, be sure
that the power supply is well grounded. Make sure to use the power cord
supplied by ITECH.
Check all marks on the instrument before connecting the instrument to power
supply.
Use electric wires of appropriate load. All loading wires should be capable of
bearing maximum short-circuit of electronic load without overheating. If there
are multiple loads, each pair of the load power cord must be carry out the full
rated short-circuit output current of the power securely.
Ensure the voltage fluctuation of mains supply is less than 10% of the working
voltage range in order to reduce risks of fire and electric shock.
Do not install alternative parts on the instrument or perform any unauthorized
modification.
Do not use the instrument if the detachable cover is removed or loosen.
To prevent the possibility of accidental injuries, be sure to use the power
adapter supplied by the manufacturer only.
Never use the instrument with a life-support system or any other equipment
subject to safety requirements.
Failure to use the instrument as directed by the manufacturer may render its
protective features void.
Always clean the casing with a dry cloth. Do not clean the internals.
Make sure the vent hole is always unblocked.
Environmental Conditions
The instrument is designed for indoor use and an area with low condensation. The
table below shows the general environmental requirements for the instrument. The
speed of fan will change intelligently by the temperature of radiator. When the
temperature is up to 40°C, the fan will be on and adjust intelligently when
temperature changes.
Environmental Conditions
Requirements
Operating temperature
0°C to 40°C
Operating humidity
20%-80% (non-condensation)
Storage temperature
-20°C to 70 °C