– 24 –
2.7.14 E
ND OF
P
RINT SIGNAL
Next parameter is useful to control the working mode of output ‘End of Print’ signal.
Printer manages one output line which reports the status of printing operations to an external device.
This signal can be activated in two different ways: during the whole printing operation or 250 msec.
long starting from the end of printing.
Please refer to programming manual for all needed details.
The message you’ll see is the next one:
End Print Signal
Disabled
You can modify this parameter by using UP and DOWN keys.
Available values are:
Signal activated during whole printing operation
Signal 250 milliseconds long starting from the end of printing operations
Disabled
When you reach the correct value, press ENTER to validate it or ESC to abort and come back to
main menu.
WARNING: The connector for End of Print signal (which will be mounted on frontal panel)
is not included into printer standard configuration; it must be ordered as
option
________________________________________________________________________________
2.7.15 S
ELECTION FOR TYPE OF PAPER SENSOR
Standard paper sensor is a “fork-type” one. Anyway it’s possible to have a reflection sensor instead
of the standard one.
With reflection sensor you can detect tags with a black mark on the lower side of medium (the
opposite side of printing); standard sensor should not be able to detect this kind of tags.
You can use standard fork sensor, instead, to detect usual labels or tags having holes.
The message you’ll see is the next one:
Paper Photosens:
Fork
You can modify this parameter by using UP and DOWN keys.
Available values are:
Fork
Reflection
When you reach the correct value, press ENTER to validate it or ESC to abort and come back to
main menu.