TROUBLESHOOTING
24
S U N f o x I N F R A S p i d e r r e m o t e
FAULT
CAUSE
REMEDY
When ignited the appliance does not work,
The POWER indicator does not come on.
1-AC power point loose or short-circuited
fuse.
2-Battery charge too low, battery pack faulty
(B1) or poles loose.
3-Infra-red receiver (D) covered.
4-The POWER button of the remote control
has not been pressed for 2 seconds.
5-Remote control faulty or batteries low.
6-Connection cables between front and rear
control boards loose or faulty.
7-Control boards faulty.
1-Repair / replace.
2-Replace batteries, tighten poles
3-Make hole for receiver.
4-Press POWER for 2 seconds, release and
press again.
5-Replace Remote Control or Batteries
6-Remedy or replace.
7-Replace.
No spark when the appliance is started.
1-Distance between the ignition device
(HV1) and the earth connection or the distance
between the electrodes (HD) is excessive.
2-The ceramic part of the ignition device (HV1)
is broken or faulty.
3-High-voltage cable loose, broken or short-
circuited.
4-No earth connection in pilot set.
5-Rear control board faulty.
1-Regulate the distance to 4 __0.5 mm.
(The cable resistance must be connected close
to the ignition device).
2-Replace the ceramic part.
3-Repair or replace.
4-Make earth connection.
5-Replace.
No flame
1-Not enough gas supply (bad LPG gasification
or dirt in system)
or pressure regulator not set properly or faulty.
2-No gas flow (tank empty or interruption in
supply) or pressure regulator faulty.
3-Sudden gust of wind (above 3 m/s) with
gas tank panels removed.
4-Dirt in gas circuit.
5-Gas leaks.
1-Clean, set / replace.
2-Check / replace.
3-Replace panels.
4-Check / clean.
5-Check / repair.
Spark ok but pilot flame does not come on.
1-No gas supply.
2-Connection faulty between front and rear
connection boards or power cables loose.
3-Pilot injector blocked.
4-Rear control board faulty.
5-Valves G1 and G2 faulty.
1-Check.
2-Reposition or replace cables.
3-Check or replace.
Nozzle diameter: LPG: 0.35 mm; NATURAL
GAS: 0.55 mm.
4-Replace.
5-Replace.
Pilot flame on, sparks continue without stop
(no flame detection).
1-Flame sensor cables (S) and ignition device
(HV) switched over or loose.
2-Flame sensor (S1) and earth short circuited.
3-Flame sensor (S1) fails to detect flame.
4-Pilot flame burns inside pilot pipe.
5-Rear control board faulty.
1-Put right.
2-Restore correct position.
3-Restore correct position.
4-Replace.
5-Replace.
Pilot flame on, the main burner does not come
on.
1-Cables faulty or terminals loosened.
2-Main burner nozzle blocked.
3-“M” and “L” valves faulty.
4-Front and rear control boards faulty.
5-Faulty remote control.
1-Repair or replace.
2-Check gas pressure, replace pilot set or
perforate injector again.
3-Check gas pressure, replace “M” and “L”
valves.
4-Replace.
5-Replace.
The low flame comes on; the medium flame
does not.
1-Cables faulty or terminals loose.
2-“M” valve faulty or “M” valve nozzle
blocked.
3-Front control board faulty.
4-Faulty remote control.
1-Repair or replace.
2-Replace.
3-Replace.
4-Replace.
The medium flame comes on; the low flame
does not.
1-Cables faulty or terminals loose.
2-“L” valve faulty or “L” valve nozzle blocked.
3-Front control board faulty.
4-Remote control faulty.
1-Repair or replace.
2-Replace.
3-Replace.
4-Replace.
During the ignition cycles, the appliance does
not go off in 25 seconds.
1-Front control board faulty.
1-Replace.
The remote control battery is down.
1-The battery is failing.
1-Replace.
Summary of Contents for INFRA Spider
Page 3: ...3 SUNfox INFRA Spider remote OK Fig 4 L min 1 5m 30 L 1 5m 1 L 2 5m L max 2 5m 30 90 1 2 Fig 5...
Page 8: ...8 SUNfox INFRA Spider remote centralina control unit telecomando remote control Fig 8 Fig 9...
Page 33: ...33 NOTE...
Page 34: ...34 NOTE...
Page 35: ...35 NOTE...
Page 36: ...3520300024 Rev 5 07 2010...