TROUBLESHOOTING: with remote control.
27
FA L O ’
FAULT
CAUSE
REMEDY
When ignited the appliance does not work,
The POWER indicator does not come on.
1-Battery charge too low, battery pack
faulty (B1) or poles loose.
2-Infra-red receiver (D) covered.
3-The POWER button of the remote control
has not been pressed for 2 seconds.
4-Remote control faulty or batteries low.
5-Connection cables between front and
rear control boards loose or faulty.
6-Control boards faulty.
7-Dump-switch failure or the floor with
inclination greater than 15¡.
1-Replace batteries, tighten poles
2-Make hole for receiver.
3-Press POWER for 2 seconds, release and
press again.
4-Replace Remote Control or Batteries
5-Remedy or replace.
6-Replace.
7-Replace, change position (floor with
inclination less than 15¡).
No spark when the appliance is started.
1-Distance between the ignition device
(HV1) and the earth connection or the distance
between the electrodes (HD) is excessive.
2-The ceramic part of the ignition device (HV1)
is broken or faulty.
3-High-voltage cable loose, broken or short-
circuited.
4-No earth connection in pilot set.
5-Rear control board faulty.
1-Regulate the distance to 4 __0.5 mm.
(The cable resistance must be connected close
to the ignition device).
2-Replace the ceramic part.
3-Repair or replace.
4-Make earth connection.
5-Replace.
No flame
1-Not enough gas supply (bad LPG gasification
or dirt in system) or pressure regulator not set
properly or faulty.
2-No gas flow (tank empty or interruption in
supply) or pressure regulator faulty.
3-Sudden gust of wind (above 3 m/s) with
gas tank panels removed.
4-Dirt in gas circuit.
5-Gas leaks.
6-cylinder connection, air in pipe
1-Clean, set / replace.
2-Check / replace.
3-Replace panels.
4-Check / clean.
5-Check/tighten connections/replace seals or pipes.
6-repeat ignition to eliminate air.
Spark ok but pilot flame does not come on.
1-No gas supply.
2-Connection faulty between front and rear
connection boards or power cables loose.
3-Pilot injector blocked.
4-Rear control board faulty.
5-Valves G1 and G2 faulty.
1-Check.
2-Reposition or replace cables.
3-Check or replace.
Nozzle diameter: LPG: 0.35 mm; NATURAL
GAS: 0.55 mm.
4-Replace.
5-Replace.
Pilot flame on, sparks continue without stop
(no flame detection).
1-Flame sensor cables (S) and ignition device
(HV) switched over or loose.
2-Flame sensor (S1) and earth short circuited.
3-Flame sensor (S1) fails to detect flame.
4-Pilot flame burns inside pilot pipe.
5-Rear control board faulty.
1-Put right.
2-Restore correct position.
3-Restore correct position.
4-Replace.
5-Replace.
Pilot flame on, the main burner does not
come on.
1-Cables faulty or terminals loosened.
2-Main burner nozzle blocked.
3-ÒMÓ and ÒLÓ valves faulty.
4-Front and rear control boards faulty.
5-Faulty remote control.
1-Repair or replace.
2-Check gas pressure, replace pilot set or
perforate injector again.
3-Check gas pressure, replace ÒMÓ and ÒLÓ
valves.
4-Replace.
5-Replace.
The low flame comes on; the medium flame
does not.
1-Cables faulty or terminals loose.
2-ÒMÓ valve faulty or ÒMÓ valve nozzle
blocked.
3-Front control board faulty.
4-Faulty remote control.
1-Repair or replace.
2-Replace.
3-Replace.
4-Replace.
The medium flame comes on; the low flame
does not.
1-Cables faulty or terminals loose.
2-ÒLÓ valve faulty or ÒLÓ valve nozzle blocked.
3-Front control board faulty.
4-Remote control faulty.
1-Repair or replace.
2-Replace.
3-Replace.
4-Replace.
During the ignition cycles, the appliance does
not go off in 25 seconds.
1-Front control board faulty.
1-Replace.
The remote control battery is down.
1-The battery is failing.
1-Replace.
Blackening of glass pipe
1-poor quality gas or gas unsuitable for winter
2-bad draught.
3-mains cylinder (optional) out of
position/deformed.
4-exchanger head dirty/damaged.
5-burner dirty/damaged.
1-use quality gas, preferably pure propane.
2-particularly windy or no wind-protection KIT.
3-reposition/replace/eliminate.
4-clean/replace.
5-clean/replace.
Glass pipe breakage
- excessive thermal shock due to particular
weather conditions.
- cleaning with unsuitable instruments.
- accidental fall of appliance.
- Replace.
- Replace.
- Replace.