CLOCK SETTING
With the card off press the TIME key for three seconds. The part of the TIME display for the hour
flashes, and can be changed using the INCREMENT and DECREMENT keys. By pressing the TIME
key again the minutes can be changed in the same way and pressing TIME once more will allow
the day of the week to be set, which is shown on the TIME display, using the strings Mon, Tues,
Weds, Thurs, Fri, Sat, Sun, (which will be shown according to the type of display). One final press
of the TIME key concludes this phase. If weekly programming is enabled after setting the clock it is
possible to move on automatically to weekly programming in order to check the coherence with
the new settings.
4.3 Alarm
Code
Display
Cause
Effect
Remedy
Err
TOP
ELEMENT
Top
sensor
fault
Current cycle stops and
buzzer
sounds
intermittently
Check the connections and
proper working condition of
the Top sensor
Err
BOTTOM
ELEMENT
Bottom sensor
fault
Current cycle stops and
buzzer
sounds
intermittently
Check the connections and
proper working condition of
the Bottom sensor
Er1
TOP AND
BOTTOM
ELEMENT
Steamer sensor
fault
Current cycle stops and
buzzer
sounds
intermittently
Check the connections and
proper working condition of
the Steamer sensor
Er2
TOP AND
BOTTOM
ELEMENT
Card/Cold
junction sensor
fault
Current cycle stops and
buzzer
sounds
intermittently
Cannot be reset
Hit
TOP AND
BOTTOM
ELEMENT
Card/Cold
junction sensor
temperature
higher than
parameter P11
Current cycle stops and
buzzer
sounds
intermittently
Wait until the temperature
drops below parameter P11
and look for the cause of
overheating
RTC
TOP AND
BOTTOM
ELEMENT
Present date
and hour not
valid
Current cycle stops and
buzzer
sounds
intermittently
To set correct present hour
and date. if the problem
persists, pls contact service
department.