4.1.4 Steam generator connection

 

 

 

 
 

               

 

 

 

WARNING! The manufacturer declines all responsibility for damage or problems caused by lack 
of observation of the required safety norms during oven installation. 

 

 

 

 

 

 

 

 

 

WATER INLET 

0,5/0,6 mbar max pressure reducer has to be installed

 

WATER DISCHARGE 

Øint. 12mm rubber hose has to be 

connected

 

Summary of Contents for BULL BLN Series

Page 1: ...rev 10 2016 USE AND MAINTENANCE MANUAL BULL...

Page 2: ...enance manual 2 INTRODUCTION The present manual provides safety directions and instructions for the oven use and maintenance This manual must be consigned to the people working on the oven or doing th...

Page 3: ...ufacturer s recommended use 3 3 Technical data 4 INSTRUCTIONS FOR INSTALLATION AND USE 4 1 Instructions for correct installation 4 1 1 Unloading and transporting the oven 4 1 2 Environmental condition...

Page 4: ...regulations the oven in your possession may appear slightly different from the one described in this booklet That will in no way effect the validity of the information and illustrations provided Any e...

Page 5: ...his plate is located on the rear of the oven Further information regarding the equipment manufacture can be obtained by reading the declaration of conformity with safety regulations enclosed with this...

Page 6: ...a Only Pizza or bread can have a direct contact with ceramic decks All other food products must be placed in a pan or container to avoid direct contact with ceramic decks Disconnect the oven at the ma...

Page 7: ...e located at the top and one at the bottom of the cooking chamber with separate controls The cooking process of BULL ovens is managed by a digital control card These heat regulation devices have been...

Page 8: ...field which is produced Connect up the outlet for the fumes to a chimney and make sure that it has a good draught make provision for a condensation release point so that no water can enter oven 4 1 1...

Page 9: ...o gain access to the terminals The oven is supplied without a mains lead and so a suitable rubber lead ETL conform of the correct absorption and insulated has to be connected Remove the protective cov...

Page 10: ...e manufacturer declines all responsibility for damage or problems caused by lack of observation of the required safety norms during oven installation WATER INLET 0 5 0 6 mbar max pressure reducer has...

Page 11: ...Use and Maintenance manual 11 4 2 Description of controls 4 2 1 User interface KEYS I N R O F L A T I Sw1 Sw2 Sw3 Sw4 Sw5 Sw6 Sw7 Sw8 Sw9 Sw10 Sw11 Sw12 Ds1 Ds3 Ds2 Ds4 A B SERIAL1...

Page 12: ...hours and minutes to days of the week CEILING key With the card in standby by pressing once it is possible to change the top elements set point With weekly programming in progress by pressing once it...

Page 13: ...all the default parameters With code entry function by pressing once it is possible to enter the first digit of the code STEAM key With program setting on by pressing once it is possible to enable cyc...

Page 14: ...The Led is on if the Bottom heating elements are on Humidity led The Led is on if the humidity is on and ready to generate steam The Led flashes if the humidity is on but not yet up to temperature Th...

Page 15: ...the BASE display flashes By pressing the HUMIDITY key the user can program the humidity activation deactivation This programming phase ends by pressing the PROG key or after a timeout given by the P8...

Page 16: ...jection manual injection can always be activated by pressing the STEAM key If a program involves automatic injection the PROG display dot is on Automatic injection can be disabled during a cycle by pr...

Page 17: ...n to displaying the cycle time press TIME See paragraph ERROR for the details of how to make settings When the time set for the cycle finishes the buzzer sounds for the amount of time set with paramet...

Page 18: ...ng HUMIDITY BOTTON the HUMIDITY rel is enabled this last only giving consent to an external device Humidity led is fixed lighted on If P15 1 the card menages directly the heating of the humidity In th...

Page 19: ...s and buzzer sounds intermittently Check the connections and proper working condition of the Top sensor Err BOTTOM ELEMENT Bottom sensor fault Current cycle stops and buzzer sounds intermittently Chec...

Page 20: ...s Clean the stainless surfaces behind the glass Be very careful not to clean and or wet the tempered glass door while still hot as the sudden drop of temperature could cause it to fracture COMPONENTS...

Page 21: ...glass by means of a screwdriver Unscrew by hand carefully the lower screws first and then the upper screws making sure the glass is not vulnerable to any stress or blows that could cause its break Whe...

Page 22: ...Use and Maintenance manual 22 Make sure that the new insulating rope is properly fastened into its location The use of a rubber hummer is recommended...

Page 23: ...____________________________________________________________________________ ________________________________________________________________________________ __________________________________________...

Page 24: ...Use and Maintenance manual 24 Italforni Pesaro S r l Via Dell industria 130 Loc Chiusa di Ginestreto 61122 Pesaro PU Italy...

Reviews: