background image

       Installation guide 

Local Control Network  -  building controls in perfection

6

Note:

 

If a variety of similar transponder types are being used, only one representative LCN-ULT 
has to be learned. If for example, an EM H4102 and/or a  HITAG 1 or HITAG S  has to be 
learned, the transponder reader then transfers several ID numbers from this transponder 
type to the LCN Bus.  
If a car key, transponder card or transponder keyring cannot be learned, you should check if 
a transponder is intregated. Most of the Mercedes models have no transponders in the key, 
they work with an immobilizer on an infrared base.   The LCN-ULT cannot read out these 
keys. 
Should a new generation of transponder chips be produced, that the   LCN-ULT   doesn´t 
know today, the transponder reader can become a new firmware update, by loading a new 
software version.  

Erasing single transponder types

Hold the master card in front of the transponder reader for longer than 5 seconds, until the 
red  LED  flashes  slowly.  Now  remove  the  master  card  again.  The  mode  „erase  single 
transponder types“ is activated.   Now hold the transponder card that has to be erased in 
front of the transponder reader, until the red LED stops flashing and the blue LED on the 
LCN-ULT lights permanently. This transponder type has now been erased from the type 
storage,  the  ID  numbers  of  several  members  in  this  transponder  family  will  not  be 

LCN-ULT

®

Summary of Contents for LCN-ULT

Page 1: ...ontrol systems time recording systems and alarm systems mechatronical lock cylinders and locks Over LCN allowance can be granted for example for access permission for electronical locked doors or othe...

Page 2: ...k building controls in perfection 2 Installation white yellow green free power supply LCN IV transponder reader LCN ULT brown to the I port of an LCN module adapter for the I port connection cable app...

Page 3: ...e Minimum distance between two LCN ULT transponder readers to avoid them from interfering with each other a possible distance of 75cm should be kept between each LCN ULT Connection LCN ULT can be conn...

Page 4: ...s such influences and reduces the transmitting power automatically When a distinctive range reduction occurs please try the function with the reading head away form its fixing point should the require...

Page 5: ...tly again Then go back into the learn mode again Preparing for operation learning new transponder types with several LCN ULT s If there are there more than one LCN ULT in the building it is possible t...

Page 6: ...ed base The LCN ULT cannot read out these keys Should a new generation of transponder chips be produced that the LCN ULT doesn t know today the transponder reader can become a new firmware update by l...

Page 7: ...ransponder reader for longer than 15 seconds When the master card is recognised the LED will flash in blue After about 5 seconds it will flash slowly in red After a further 10 seconds the slow flashin...

Page 8: ...reated to combine many LCN ULT s into a group or commission This is possible with an order of over 5 LCN ULT s When ordering you must state how many transponder readers and how many master cards that...

Page 9: ...parts have to be sent together for repairs or replacements When a master card is lost a replacement delivery is possible Unknown transponders firmware updates Should there be an unknown transponder o...

Page 10: ...one Function Feedback LED Action with mit car key Installation guide Local Control Network building controls in perfection 10 LCN ULT new key type transponder type learning with an LCN ULT with severa...

Page 11: ...11 Installation guide Local Control Network building controls in perfection LCN ULT Dimensions of the reader...

Page 12: ...s can be obtained from the technical hotline 30 C to 70 C IP65 68mm flush mounted box 80mm x 80mm 11 7mm 27 7mm white optional silver ASA water and UV resistant 2 fine wire 4x 0 14mm wire ends tinned...