Isotra ZIP ECO Measurement And Assembly Manual Download Page 2

  

 

MEASUREMENT AND ASSEMBLY MANUAL 

Manual validity: 01.02.2015 

COLOUR: 

Box and guide bars: 

 

Standard version: ral 9006 (light silver), ral 9007 (dark silver), ral 7016 (anthracite grey); 

 

Other colours can be selected from the ral colour chart. 

Plastic components cannot be painted. 

 

2. SCOPE OF USE 

The installation should be carried out in accordance with this manual in order to avoid unnecessary errors or other related 

troubles. 

The  roller  blind  was  designed  for  use  in  both  internal  and  external  installations.  The  motor  is  moisture-proof,  with  ip44 

protection rating. The roller blind is not intended for use in explosive environments. The service switch should be installed 

indoors.  It  is  possible  to  install  the  switch  outdoors  but  only  with  corresponding  protection  preventing  the  penetration  of 

water and protecting all electrical components. 

 

Power supply: 

Electric power mains 230 v ac; 

Frequency 50

–60 hz; 

Voltage fluctuation tolerance ±10%; 

Interference level below 70 db. 

 

Operating conditions: 

Ambient temperature -

5 °c t50 °c; 

Relative humidity up to 5 g/m3 and 75% (class i2); 

Atmospheric conditions e11, e12, e14, e15 as per en 13561; 

Wind resistance * 

Motorised version 

– class 3 beaufort scale 6 (max. 49 km/h); 

Crank version 

– class 0–2 (depends of the model). 

*in case of outdoor installation: if adverse weather conditions arise, it is strongly recommended to draw the roller blind up 

to the box. For motorised roller blinds, it is recommended to use a wind sensor for the automatic roller drawing to the box. 

 

3. OPERATOR REQUIREMENTS 

All activities described for the installation, maintenance, and control of the motor limit switches should only be carried out 

by specialised, qualified personnel. Anyone can use the roller blinds on a daily basis. 

 

 

 

 

Summary of Contents for ZIP ECO

Page 1: ...n front of an opening As a rule indicate the width of the opening which is to be shaded in the order form 2 x 40 mm Dimensions outside the stipulated limits must be consulted with the manufacturer H h...

Page 2: ...enting the penetration of water and protecting all electrical components Power supply Electric power mains 230 v ac Frequency 50 60 hz Voltage fluctuation tolerance 10 Interference level below 70 db O...

Page 3: ...scaffolds balconies etc or at elevated bridges If it is impossible to use such facilities suitable individual protection means must be used The scaffolds platforms and elevated working areas must be e...

Page 4: ...e using portable drills and screwdrivers 2 Roller blind installation to a frame or wall 3 Connection to power mains 4 Adjustment of end stops motor limit switches etc and testing of the roller blind P...

Page 5: ...zipper moves A Aluminium guide rail B Plastic guide rail 1 Insert the guide rails in the side piece mandrel check if height of the guide rails is the same 2 Cut the plastic guide rail to size with the...

Page 6: ...s together with the control unit in all situations where there is more than one device to control the same roller blind The control unit will store the provided impulse for approx 3 minutes or until r...

Page 7: ...brown phase neutral conductor yellow green ground Motor switching can be installed in two different ways either using a switch or using a programming set on request The instructions for programming an...

Page 8: ...eed assistance contact your dealer and ask for original spare parts DISASSEMBLY DISPOSAL As regards Directive 2002 95 EC RoHS on the use of lead chrome cadmium and other substances hazardous to enviro...

Page 9: ...tape directly onto the winding drum on the side opposite to where the fabric is moving Repeat applying further adhesive tape layers until the defect is completely removed Drum cover displacement If th...

Page 10: ...ng operation Otherwise contact technical support Increased noise Motor failure Disconnect the motor test it and replace if necessary Motor blocks after a long period of service The motor is in the the...