MS1000 – SENSOR MANUAL

1000_EN_IT_IS_R0_PED

s

hrewdness

 

and

 P

recautions

NO

YES

OPERATING TEMPERATURES

EBONITE LINING

PP LINING

PTFE LINING

Liquid 

temperature

Ambient 

temperature

Liquid

 

temperature

Ambient 

temperature

Liquid

 

temperature

Ambient 

temperature

Min.

Max

Min.

Max

Min.

Max

Min.

Max

Min.

Max

Min.

Max

°C

0

80

-5

60

0

60

0

60

-20

130

-10

60

°F

30

176

23

140

32

140

32

140

-4

266

14

140

LONG PIPE

LONG PIPE

ANTI VIBRATION JOINTS

3 DN

2 DN

 

GASKET THI4mm

For vertical installations 

with descending flow 

direction contact the 

manufacturer

Avoid the installation of 

the sensor in a long pipe 

line,without any support 

of the same

Avoid the functioning 

with the pipe partially 

empty

Avoid the installation 

near curves or hydraulic 

accessories

Avoid the approach of 

the flange and counter 

flange using the closing 

force of the nuts

For vertical installations is 

preferable an ascending 

flow

For installations on long 

pipe line, please use the 

anti vibration joints

During the functioning the 

pipe must be completely 

full of liquid, or completely 

empty

Install the sensor away 

from curves and hydraulic 

accessories

Before tightening the nuts 

approach as more possible 

the flange of the piping to 

the flange of the sensor

Summary of Contents for MS 1000

Page 1: ...INSTRUCTION MANUAL MS 1000...

Page 2: ...L DIMENSIONS______________________________________ 3 OPERATING TEMPERATURES__________________________________ 4 ELECTRICAL CONNECTIONS OF SENSOR TO CONVERTER____________ 5 GROUNDING INSTRUCTIONS______...

Page 3: ...ion to the converter consider the operating temperatures more restrictive otherwise refer to the respective manuals page 5 When transporting unpacking and handling the flowmeter be careful and care In...

Page 4: ...ON THE SENSORS INSTALLATION Lifting sensors The sensors with eyebolts must be lifted by the method shown below The eye bolt are measured to sustain exclusively the weight of the meter Before install t...

Page 5: ...200 7 87 250 9 84 300 11 81 350 13 78 400 15 75 H 147 5 79 153 6 02 161 6 34 177 6 97 199 7 83 209 8 23 235 9 25 263 10 35 291 11 46 362 14 25 417 16 42 467 18 39 527 20 75 579 22 80 D 62 2 20 67 2 44...

Page 6: ...ction contact the manufacturer Avoid the installation of the sensor in a long pipe line without any support of the same Avoid the functioning with the pipe partially empty Avoid the installation near...

Page 7: ...SORS MODEL NO CONNECTIONS SEPARATE WITHOUT JUNCTIONS BOX STAINLESS STEEL MODEL NO CONNECTIONS REQUIRED CABLE ALREADY CONNECTED AND POTTED SEPARATE WITH JUNCTIONS BOX WITH OR WITHOUT PREAMPLIFIER ALL C...

Page 8: ...sensor must be install in the piping with a cathodic protection is necessary using insulating bushes to isolate the bolts Grounding metallic rings should be provided to ground the liquid using insula...

Page 9: ...52 68 35 65 75 45 53 80 41 53 68 100 56 83 94 125 71 112 130 150 106 135 113 200 288 433 250 408 455 300 510 683 350 598 946 400 821 911 Tighten uniformly in diagonally opposite sequence The torque li...

Page 10: ...1200 I I I I 1300 I I I I 1400 I I I I 1500 I I I I 1600 I I I I 1700 I I I I 1800 I I I I 2000 I I I I 2400 I I I I tab a ped directive for water with temperature 110 c all lining pp ebonite ptfe DN...

Page 11: ...2 Temperatura massima del liquido 110 C Model family MS 2500 MS1000 MS2410 Conformity assessment procedure applied Allegato II categoria I Modulo A Standard reference UNI EN 13480 3 Hemina declares t...

Page 12: ...aly 27 via F lli Gracchi Phone 39 02 66027 1 Fax 39 02 6123202 E mail isomagservice isoil it Isoil Industria spa Head office 20092 Cinisello Balsamo MI Italy 27 via F lli Gracchi Phone 39 02 66027 1 F...

Reviews: