background image

8

MS1000 – SENSOR MANUAL

1000_EN_IT_IS_R0_PED

NOTES FOR  PED  DIRECTIVE FOR SENSOR

Here below the tables of  products subject to Directive 97/23/EC. 

The models are : MS1000/MS2410/MS2500. 

The tables show which category of  PED is applicable according to the water operating 

temperature (TAB A T <110 ° C TAB B T> = 110 ° C), sensor’s DN  and its nominal pressure.

DN

NOMINAL PRESSURE (PN)

10

16

25

40

25

USE PN 40

E

32

E

40

E

50

USE 

PN 16

E

USE 

PN 40

E

65

E

E

80

E

E

100

E

E

125

E

E

150

E

E

200

E

E

E

E

250

I

I

I

I

300

I

I

I

I

350

I

I

I

I

400

I

I

I

I

450

I

I

I

I

500

I

I

I

I

600

I

I

I

I

700

I

I

I

I

800

I

I

I

I

900

I

I

I

I

1000

I

I

I

I

1200

I

I

I

I

1300

I

I

I

I

1400

I

I

I

I

1500

I

I

I

I

1600

I

I

I

I

1700

I

I

I

I

1800

I

I

I

I

2000

I

I

I

I

2400

I

I

I

I

tab

a

Ped

 

directive

 

for

 

water

 

with

 

temPerature

 <110°

c

aLL

 

Lining

 : 

PP

ebonite

,

Ptfe

DN

NOMINAL PRESSURE (PN)

10

16

25

40

25

USE PN 40

E

32

E

40

II

50

USE 

PN 16

I

USE 

PN 40

II

65

I

II

80

I

II

100

I

II

125

I

II

150

I

II

200

I

I

II

II

250

I

II

II

II

300

I

II

III

III

350

I

III

III

III

400

II

III

III

III

450

II

III

III

III

500

II

III

III

III

tab

b

Ped

 

directive

 

for

 

water

 

with

 

temPerature

 >=110°

c

onLy

 

Ptfe

 

Lining

Legenda

E

OUT OF DIRECTIVE

I

PED CAT. I

II

PED CAT. II

III

PED CAT. III

For products that falls in category I,  is valid the declaration of conformity available on the 

following page; the products in Category II and III are supplied with a specific declaration of 

conformity for each instrument

Summary of Contents for MS 1000

Page 1: ...INSTRUCTION MANUAL MS 1000...

Page 2: ...L DIMENSIONS______________________________________ 3 OPERATING TEMPERATURES__________________________________ 4 ELECTRICAL CONNECTIONS OF SENSOR TO CONVERTER____________ 5 GROUNDING INSTRUCTIONS______...

Page 3: ...ion to the converter consider the operating temperatures more restrictive otherwise refer to the respective manuals page 5 When transporting unpacking and handling the flowmeter be careful and care In...

Page 4: ...ON THE SENSORS INSTALLATION Lifting sensors The sensors with eyebolts must be lifted by the method shown below The eye bolt are measured to sustain exclusively the weight of the meter Before install t...

Page 5: ...200 7 87 250 9 84 300 11 81 350 13 78 400 15 75 H 147 5 79 153 6 02 161 6 34 177 6 97 199 7 83 209 8 23 235 9 25 263 10 35 291 11 46 362 14 25 417 16 42 467 18 39 527 20 75 579 22 80 D 62 2 20 67 2 44...

Page 6: ...ction contact the manufacturer Avoid the installation of the sensor in a long pipe line without any support of the same Avoid the functioning with the pipe partially empty Avoid the installation near...

Page 7: ...SORS MODEL NO CONNECTIONS SEPARATE WITHOUT JUNCTIONS BOX STAINLESS STEEL MODEL NO CONNECTIONS REQUIRED CABLE ALREADY CONNECTED AND POTTED SEPARATE WITH JUNCTIONS BOX WITH OR WITHOUT PREAMPLIFIER ALL C...

Page 8: ...sensor must be install in the piping with a cathodic protection is necessary using insulating bushes to isolate the bolts Grounding metallic rings should be provided to ground the liquid using insula...

Page 9: ...52 68 35 65 75 45 53 80 41 53 68 100 56 83 94 125 71 112 130 150 106 135 113 200 288 433 250 408 455 300 510 683 350 598 946 400 821 911 Tighten uniformly in diagonally opposite sequence The torque li...

Page 10: ...1200 I I I I 1300 I I I I 1400 I I I I 1500 I I I I 1600 I I I I 1700 I I I I 1800 I I I I 2000 I I I I 2400 I I I I tab a ped directive for water with temperature 110 c all lining pp ebonite ptfe DN...

Page 11: ...2 Temperatura massima del liquido 110 C Model family MS 2500 MS1000 MS2410 Conformity assessment procedure applied Allegato II categoria I Modulo A Standard reference UNI EN 13480 3 Hemina declares t...

Page 12: ...aly 27 via F lli Gracchi Phone 39 02 66027 1 Fax 39 02 6123202 E mail isomagservice isoil it Isoil Industria spa Head office 20092 Cinisello Balsamo MI Italy 27 via F lli Gracchi Phone 39 02 66027 1 F...