background image

7A 

-

 

  3. Lamp   

 

 

 

 

Because of its high internal pressure, there might be a risk that the Discharge lamp would 
explode  during  operation.  The  lamp  emits  intense  UV  radiation  which  is  harmful  to  the 
eyes  and  skin.  The  high  luminance  of  the  arc  can  cause  severe  damage  to  the  retina  if 
looks directly at the lamp. 
 
    Discharge lamp: 

MSD 250/2 GY 9.5 

 

1. Always switch off the main supply and never handle the lamp or luminaries when is hot. 
2. Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured 

alcohol and wipe it with a lint free cloth before installation. 

3. The lamp generates UV radiation. Never operate the lamp without appropriate shielding. 
4. When  burning,  the  lamp  operates  at  high  pressure  and  there  is  a  slight  risk  of  arc  tube 

rupture.  The  risk  increases  with  age,  temperature  and  improper  handling  of  the  lamp.  Do 
not use the lamp any longer than its specified life.   

5. Make  sure the  lamp is located in the  center  of the  reflector for the  best  spot.  Adjust  lamp 

position by screws A, B and C. 

 

 

 

 

i.) Channel 14 

Pre-programmed show pattern: 

1.)  DMX value 0-31,the fixture is still controlled by DMX control . 
2.)  For DMX Value above 31,all the DMX control will be invalid .The fixture will 

run the pre-programmed show patterns(Pan/Tilt movement). 

ii.) Channel 15-Pre-programmed beam pattern: 

One can select the beam pattern only when the pre-programmed show pattern is 
activated. 

iii.) For DMX Reset, put DMX value of CH-8 & CH-16 to 255. 
 
 
 
 
 
 
 
 
 

 

In case of replacement of the lamp or maintenance, do not open the 

  fixture within 15 minutes until the unit cools down after switching off.

Summary of Contents for iMOVE 8W

Page 1: ...Innovation Quality Performance iMove 8W Moving Wash WWW BEGLEC COM...

Page 2: ...hting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000...

Page 3: ...rials close to the unit while operating as it is fire hazard l Use safety chain when fixes this unit Don t handle the unit by taking its head only but always by taking its base l Maximum ambient tempe...

Page 4: ...t to rain or moisture l Never touch bulb with bare fingers as it is very hot after using l Hot lamp explosion hazard Do not open the unit within five minutes after switching off l Do not start on the...

Page 5: ...g A The unit does not work no light and the fan does not work 1 Check the connect power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED B Not responding to DMX...

Page 6: ...rroded connectors can easily distort the signal and shut down the system 4 The DMX output and input connectors are pass through to maintain the DMX circuit when power is disconnected to the unit 5 Eac...

Page 7: ...erates at high pressure and there is a slight risk of arc tube rupture The risk increases with age temperature and improper handling of the lamp Do not use the lamp any longer than its specified life...

Page 8: ...ramming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions Remote controller input By connect to the 1 4 microph...

Page 9: ...w 4 Please refer to 4 2 Main Functions Show mode Color selection X Y moving setting 1 Pan position 2 Tilt position 3 Dimmer First set Master unit then set Slave units position Mode Sound 1 LED off Sou...

Page 10: ...at the remote control on the first unit will control all the other units for Stand by Function and Mode Channel Mode Press the MENU button up to when the is shown on the display Pressing ENTER button...

Page 11: ...splay Pressing ENTER button and the display will blink Use DOWN and UP button to select the Led on or Led off mode Once the mode has been selected press the ENTER button to setup or automatically retu...

Reviews: