6A 

-

 

  5.5. DMX512 Connection 

 

The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels. 

 

1. If you use a controller with 5 pins DMX connector, you need to use a 5 to 3 pin adapter. 
2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W 

resistor  between  pin  2(DMX-)  and  pin  3(DMX+)  into  a  3-pin  XLR-plug  and  plug  it  in  the 
DMX-output of the last unit. 

3. Connect the unit together in a 

daisy chain

 by XLR plug from the output of the unit to the 

input  of the next  unit. The  cable cannot  be  branched  or  split  to  a 

Y

  cable.  DMX512  is  a 

very  high-speed  signal.  Inadequate  or  damaged  cables,  soldered  joints  or  corroded 
connectors can easily distort the signal and shut down the system. 

4. The DMX output and input connectors are pass-through to maintain the DMX circuit, when 

power is disconnected to the unit. 

5. Each lighting unit needs to have an address set to receive the data sent by the controller. 

The address number is between 0-511 (usually 0 & 1 are equal to 1). 

6. The end of the DMX512 system should be terminated to reduce signal errors. 
7. 3 pin XLR connectors are more popular than 5 pins XLR. 

3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)   

5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 

      8 Channels: 
 

Channel 1 = Pan motion 
Channel 2 = Tilt motion 
Channel 3 = Shutter 
Channel 4 = Effect wheel 
Channel 5 = Color 
Channel 6 = CYM Mix Color 
Channel 7 = Dimmer 
Channel 8 = CMY Speed 

   

  Dimension: 

397 x 360 x 512 mm (L x W x H) 

  Weight: 

27 kg 

 
Luminous intensity: 

 

 

 

 

 
 
 
 
 
 
 

Summary of Contents for iMOVE 8W

Page 1: ...Innovation Quality Performance iMove 8W Moving Wash WWW BEGLEC COM...

Page 2: ...hting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000...

Page 3: ...rials close to the unit while operating as it is fire hazard l Use safety chain when fixes this unit Don t handle the unit by taking its head only but always by taking its base l Maximum ambient tempe...

Page 4: ...t to rain or moisture l Never touch bulb with bare fingers as it is very hot after using l Hot lamp explosion hazard Do not open the unit within five minutes after switching off l Do not start on the...

Page 5: ...g A The unit does not work no light and the fan does not work 1 Check the connect power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED B Not responding to DMX...

Page 6: ...rroded connectors can easily distort the signal and shut down the system 4 The DMX output and input connectors are pass through to maintain the DMX circuit when power is disconnected to the unit 5 Eac...

Page 7: ...erates at high pressure and there is a slight risk of arc tube rupture The risk increases with age temperature and improper handling of the lamp Do not use the lamp any longer than its specified life...

Page 8: ...ramming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions Remote controller input By connect to the 1 4 microph...

Page 9: ...w 4 Please refer to 4 2 Main Functions Show mode Color selection X Y moving setting 1 Pan position 2 Tilt position 3 Dimmer First set Master unit then set Slave units position Mode Sound 1 LED off Sou...

Page 10: ...at the remote control on the first unit will control all the other units for Stand by Function and Mode Channel Mode Press the MENU button up to when the is shown on the display Pressing ENTER button...

Page 11: ...splay Pressing ENTER button and the display will blink Use DOWN and UP button to select the Led on or Led off mode Once the mode has been selected press the ENTER button to setup or automatically retu...

Reviews: