    1.   Safety   Instruction       

   

   

WARNING

   

Please   keep   this   User   Guide   for   future   consultation.   If   you   sell   the   unit   to   another   user,   be   sure   

that   they   also   receive   this   instruction   booklet.   

 

Unpack   and   check   carefully   there   is   no   transportation   damage   before   using   the   unit.   

 

Before    operating,    ensure    that    the    voltage    and    frequency    of    power    supply    match    the    power   

requirements   of   the   unit.       

 

It’s   important   to   ground   the   yellow/green   conductor   to   earth   in   order   to   avoid   electric   shock.   

 

The   unit   is   for   indoor   use   only.   Use   only   in   a   dry   location.   

 

The   unit   must   be   installed   in   a   location   with   adequate   ventilation,   at   least   50cm   from   adjacent   

surfaces.   Be   sure   that   no   ventilation   slots   are   blocked.       

 

Disconnect   main   power   before   replacement   or   servicing.       

 

Make   sure   there   are   no   flammable   materials   close   to   the   unit   while   operating   as   it   is   fire   hazard.       

 

Use   safety   cables   when   fixing   this   unit.   DO   NOT   handle   the   unit   by   its   head   only,   always   carry   by   

its   base.           

 

Maximum   ambient   temperature   is   Ta:   40   degrees   C.   DO   NOT   operate   it   where   the   temperature   

is   higher   than   this.   

 

Unit    surface    temperature    may    reach    up    to    75    degrees    C.    DO    NOT    touch    the    housing    with   

bare-­‐hands   during   its   operation.   Turn   off   the   power   and   allow   about   15   minutes   for   the   unit   to   

cool   down   before   replacing   or   serving.   

 

In   the   event   of   a   serious   operating   problem,   stop   using   the   unit   immediately.   Never   try   to   repair   

the   unit   by   yourself.   Repairs   carried   out   by   unskilled   people   can   lead   to   damage   or   malfunction.   

Please    contact    the    nearest    authorized    technical    assistance    center.    Always    use    the    same    type   

spare   parts.   

 

DO   NOT   touch   any   wire   during   operation   as   high   voltage   may   cause   electric   shock.   

Warning:   

 

To    prevent    or    reduce    the    risk    of    electrical    shock    or    fire,    do    not    expose    the    unit    to    rain    or   

Please   read   the   instruction   carefully   which   includes   important   

information   about   the   installation,   usage   and   maintenance.   

Summary of Contents for iMove 350SR

Page 1: ...User Manual Please read the instruction carefully before use...

Page 2: ...Control Panel 5 3 2 Main Function 6 3 3 Home Position Adjustment 13 4 How To Control The Unit 15 4 1 Master Slave Built In Pre program Function 15 4 2 Easy CA 8 Controller 16 4 3 DMX Controller 16 4 4...

Page 3: ...d Use safety cables when fixing this unit DO NOT handle the unit by its head only always carry by its base Maximum ambient temperature is Ta 40 degrees C DO NOT operate it where the temperature is hig...

Page 4: ...ich you are attaching the unit is secure and is able to support a weight of 10 times of the fixtures weight Always use a safety cable that can hold 12 times of the weight of the fixture when installin...

Page 5: ...asy navigation Manually adjustable beam angle 12 17 0 100 smooth dimming and variable strobe speeds Data In Out 5 PIN XLR sockets RDA Remote DMX addressing DMX address can be remotely set up by univer...

Page 6: ...on MENU To select the programming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions 7 MAINS IN PowerCon connect...

Page 7: ...unctions press the MENU button until the required function is showing on the display Select the function by pressing the ENTER button and the display will blink Use the DOWN UP buttons to change the m...

Page 8: ...7...

Page 9: ...enu mode Show Mode To select the Show Mode press the ENTER button to show SHOW MODE on the display Use the DOWN and UP buttons to select the Show 1 Show 2 or Show 3 Show 4 Mode Once the mode has been...

Page 10: ...lected press the ENTER button to setup to go back to the functions without any change press the MENU button again Press and hold the MENU button for about one second or wait for one minute to exit the...

Page 11: ...us press the ENTER button to show GOBO FOCUS on the display Use the DOWN and UP buttons to adjust the value from 0 to 255 press the ENTER button to setup to go back to the functions without any change...

Page 12: ...it for one minute to exit the menu mode Temprature To select the Temp press the ENTER button to show TEMP on the display and the display will show the temperature of the unit To go back to the functio...

Page 13: ...tomatic mode for non professional users detailed explanation as followings Channel Mode 15Chan Split Color Mode No Slave Mode Slave 1 Black Out No Sound State On Sound Sense 90 Pan Inverse No Tilt Inv...

Page 14: ...DOWN buttons to choose the submenu press the ENTER button to store and automatically return to the last menu Press the MENU button to exit PAN OFFSET Pan home position adjustment To select the Pan Of...

Page 15: ...T on the display Use the DOWN and UP buttons to adjust the value from 127 to 127 press the ENTER button to store Press the MENU button to exit GOBO 2 OFFSET Gobo2 home position adjustment To select th...

Page 16: ...ster Slave Built In Preprogrammed Function By linking the units in master slave connection the first unit will control the other units to give an automatic sound activated synchronized light show This...

Page 17: ...units you will need to set DMX address from 1 to 512 so that the units can receive DMX signal Press the MENU button up to when the DMX Address is showing on the display Pressing ENTER button and the...

Page 18: ...17 4 4 DMX512 Configuration 15 Channels Mode...

Page 19: ...18 16 Channels Mode...

Page 20: ...19...

Page 21: ...the unit to the input of the next unit The cable can not branched or split to a Y cable The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is...

Page 22: ...high voltage cables that may cause interference C Some units don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode sign...

Page 23: ...tion and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN6100...