background image

3- 

H. If The pan belt is broken 

1. Turn off the main power. 

2. Unscrew all the screws (A) and open the base-housing cover (B). 

3. Unplug all the connect wires (C) that from the arm to PC board and igniter. 

4. Unscrew the screws (D) that fix the bridge (E). 

5. Unscrew the screws (F) that fix the axis gear (G). 

6. Change a new belt (H) by going through all connecting wires that from the arm to base, 

and through the bridge for correct position.   

7. Set up the gear axis to the bridge and screwed it. Note: do not press the belt. 

8. Put the belt around the axis gear and motor gear. 

9. Plug all the connect wires (C) that form the arm to PC board and igniter. 

10. Adjust the pan home position. 

11.Screw the base-housing cover (B). 

 

 

A

A

B

B

C

F

D

E

H

D

G

A

 

       

 

 

  1. Safety Instruction   

 

 

 

WARNING

 

♦ 

Please keep this User Guide for future consultation. If you sell the unit to another 

user, be sure that they also receive this instruction booklet. 

♦ 

Unpack and check carefully there is no transportation damage before using the unit. 

♦ 

Before operating, ensure that the voltage and frequency of power supply match the 

power requirements of the unit. 

♦ 

The unit is designed for use with the HTI 150W. Do not use any other type of lamp. 

♦ 

It

s important to ground the yellow/green conductor to earth in order to avoid electric 

shock. 

♦ 

The unit is for indoor use only. Use only in a dry location. 

♦ 

The unit must be installed in a location with adequate ventilation, at least 50cm from 

adjacent surfaces. Be sure that no ventilation slots are blocked. 

♦ 

Disconnect main power before fuse/lamp replacement or servicing. 

♦ 

Replace fuse/lamp only with the same type. 

♦ 

Make sure there are no flammable materials close to the unit while operating, as it 

is fire hazard. 

♦ 

Use safety cable when fixes this unit. Don

t handle the unit by taking its head only, 

but always by taking its base. 

♦ 

Maximum ambient temperature is Ta : 40

. Don

t operate it where the temperature 

is higher than this. 

♦ 

Unit surface temperature may reach up to 85

. Don

t touch the housing bare-hand 

during its operation. Turn off the power and allow about 15 minutes for the unit to 

cool down before replacing bulb or serving. 

♦ 

In the event of serious operating problem, stop using the unit immediately. Never try 

to repair the unit by yourself. Repairs carried out by unskilled people can lead to 

damage or malfunction. Please contact the nearest authorized technical assistance 

center. Always use the same type spare parts. 

♦ 

Don

t connect the device to any dimmer pack or power pack. 

♦ 

Do not touch any wire during operation as high voltage might be causing electric 

shock. 

 

Please read carefully the instruction, which includes important 

information about the installation, usage and maintenance. 

Summary of Contents for IH9000-1

Page 1: ...ower AC 120V 60Hz or AC 230 240 250V 50 60Hz Fuse 20mm Glass T6 3A Fast Blow Lamp HTI 150W Dimension 373mm x 295mm x 451 mm Weight 13 kg Innovation Quality Performance IH9000 1 User Guide Professional...

Page 2: ...damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean t...

Page 3: ...in order to avoid electric shock The unit is for indoor use only Use only in a dry location The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be...

Page 4: ...work 1 Check the connection of power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED B Not responding to DMX controller 1 DMX LED should be on If not check DMX...

Page 5: ...ected to the unit 5 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of the DMX512 sy...

Page 6: ...cover If you wish to use other forms and patterns as the standard gobos or if the gobos are to be exchanged remove the fixation ring with an appropriate tool Remove the gobo and insert the new gobo Pr...

Page 7: ...he display stops blinking or storing automatically 8 seconds later To go back to the functions without any change press the MENU button again Please refer to the following diagram to address your DMX5...

Page 8: ...r some noises for about 20 seconds After that the unit will be ready to receive DMX signal or run the built in programs 5 1 Master Slave Built In Preprogrammed Function You can select blackout mode in...

Page 9: ...hen the is blinking on the display Pressing ENTER button and all channels of the unit will return to their standard position To go back to the functions press the MENU button again 4 2 Main Function T...

Page 10: ...button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the normal or split color mode Once the mode has been selected press...

Reviews: