Users Manual
Pronomic MKA-12 Pro Aktivmonitor
Version 01/2012
Page 1: ...Users Manual Pronomic MKA 12 Pro Aktivmonitor Version 01 2012 ...
Page 2: ...ratus near water or in locations where condensation may occur 6 Clean only with dry cloth Do not use aerosol or liquid cleaners Unplug this apparatus before cleaning 7 Do not block any of the ventilation openings Install in accordance with the manufacturers instruction 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus that produce heat 9 Do not defea...
Page 3: ...s XLR type for Mic Inputs as well as 1 4 TRS tip ring sleeve input jack 5 EQ CONTROL To adjust the EQ control for setting the balance of system 6 TAPE IN Signal in for CD Player PC Computer MP 3 Player 7 TAPE GAIN Adjusts the TAPE level 8 MASTER VOLUME This knob adjusts all signal input or Mic level 9 PEAK INDICATOR The PEAK indicator built to prevent the amplifier outputs from over driving the tr...
Page 4: ...r 1kHz max THD 1 Connections 300 4 Ohms W SPL 1W 1m dB 100 Frequency Response Hz 10dB 50 20k Coverage HxV 90x40 CONNECTIONS Signal Cable with 1 4 TRS connector Signal Cable with XLR connector External Speakon Connector Line input 1x XLR 1x 6 3 mm jack balanced Mic Input XLR TRS Combo gain control Tape input RCA stereo volume control 2 band EQ Bass Top Master Volume Speakon connector for external p...