ANCHOR
PLATE
INSWOOL
BLANKET
SMOKE DOME
TOP PLATE
METAL
FLUE
Class A Metal Flue
Magnum 86072 Series fireplace is tested and listed for
use with factory-built metal, Class “A” (solid fuel) chimneys
as an option. Any Class “A” or UL 103 listed metal chimney
system is accetable for use on an Isokern system. (Figure 106)
Class “A” Metal Flue Types:
The selected factory-built metal chimney for use with
the fireplaces, at a minimum, must be listed by a recognized
agency for solid fuel and as tested to UL 103, for continuous use
of one thousand degrees (1000°) Fahrenheit and intermittent
use of seventeen hundred degrees (1700°) Fahrenheit.
The factory-built metal flue design can be from the following
types:
1. Non-insulated completely thermal siphoning, double-wall,
air-cooled solid fuel rated chimneys listed to UL 103, ULC
S629.
2. Double-wall with solid-pack insulation.
3. A combination of double-wall, solid-pack insulation and air
space (triple-wall).
4. Triple-wall air space solid fuel chimney.
5. Listed chimney liners conforming with the seventeen
hundred degree (1700°) Fahrenheit requirements of UL 1777 or
ULCS635 or ULC640 may also be used with Isokern fireplaces.
Notes:
The selected, approved chimney manufacturer must
provide the masonry anchor plate designed to fit their flue
system. (Figure 106)
All chimneys and chimney liners must be installed in
accordance with the manufacturer’s installation instructions
and under the terms of their listing for use with open faced
fireplaces.
51
FIGURE 106
Summary of Contents for Magnum 86072-60
Page 2: ......
Page 40: ...40 DM Chimney System Lateral Support cont FIGURE 81 FIGURE 82 ...
Page 55: ...55 Notes ...