30
User
Identifier
Example:
Pump P3A
9 character string
Tag No.
Example:
1FT-3011
9 character string
Test
Installation
Control system simulation: A cyclic repetition of in-
creasing flow velocity across the measureable
range. All configured outputs respond as if this
was a measured change in flow.
Yes, No
Display
Display screen test routine
Keypad
Keypad test routine
Memory
Memory test routine, Memory erase yes/no
Peripherals
Unit temperature, time, date, clock, battery meter,
charger test routine
Ultrasonics
Tests ultrasonic board and sensors
Settings
Date
Example:
03/10/07
Time
Example:
09:27:00
Date Format
Select from list ↑↓
dd/mm/yy
mm/dd/yy
yy/mm/dd
Language
Select from list ↑↓
As installed
Keypad
Enable keypad sound
Yes
No
Defaults
Reload factory default settings, except for date
and time
Yes
No
Diagnostics
Temperature
Shows control unit temperature
Log Memory
Percentage of unused datalogger memory,
estimated time remaining
Datalogger
Interval
A value of zero turns the datalogger off, a non-
zero value turns the datalogger on and defines the
logging interval.
0 ... 999 s
Selection
Select up to 10 items from list ↑↓
ENTER to select, 0 to remove
Available items as in list for display / output
Low Memory
Warning output: The amount of memory remain-
ing at which the flowmeter begins to give an audi-
ble warning.
4 ... 100 %
Log Download
Sends logger content to serial
communication port.
Log Erase
Erase datalogger
Yes / no
Serial Comms
Mode
Select from list ↑↓
None
Printer, Diagnostic, Log download,
Calibration Test (not normally used by user)
Baud
Select from list ↑↓