By pressing the "Hold" button in the MIN/MAX mode you can stop the measurements from being recorded and by pressing it 
again you can allow their recording to continue. If you stop the recording, the current measurement shown is held and the  

bargraph display frozen. 

In the MIN.MAX mode, the minimum or maximum value is shown on the digital display while the bargraph display continues to  

show the normal measurements. 

9. Relative button (REL)—

 Pressing the "REL" button causes REL to appear on the display and activates the relative mode.  

                                             When you do this, the value shown on the display is stored as a reference value and the display is  

                                             reset to zero. To exit the relative mode, hold the "REL" button pressed for two seconds. 

                                                 In the relative mode, the value displayed is the difference between the reference value held in store  

                                             and the value currently measured, e.g. if the reference value is 0.04

Ω

 and the value currently  

                                             measured is 15.05

Ω

, what appears on the display is 15.01

Ω

10.

 

HOLD button

 — Except in the MIN/MAX mode, this button is used to switch the data hold mode on and off. When the hold  

                                  mode is on, "

>

" appears on the display and the measurement shown is held until the hold button is  

                                  pressed again. The internal sounder will operate when the hold mode is switched on. 

                                    If the MIN/MAX button is pressed while the hold mode is on, the meter exits the hold mode and goes over  

                                  to the MIN/MAX mode. 

                                  If the hold button is pressed while the MIN/MAX mode is on, storage of the minimum or maximum values is  

                                  stopped, and it resumes again if the hold button is pressed for a second time. 

                                   During the hold mode the automatic power off is disabled. 

11.

 

Power reset button (PWR RST) —

 If the meter has switched itself off automatically, it can be switched back on by pressing  

                                                                this button. 

12.

 

Manual range button —

 This button is used to select manual range setting and to change ranges. If the button is pressed  

                                               once, the "



" annunciator on the display disappears. By pressing the button repeatedly, the  

                                               meter can then be set to the desired range. To revert to autoranging, hold the button pressed for  

                                               two seconds. 

Summary of Contents for IDM101

Page 1: ...Instruction Manual IDM101 Digital Multimeter EN FR IT DE JP...

Page 2: ...1 ISO TECH IDM101 Digital Multimeter INSTRUCTION MANUAL...

Page 3: ...2...

Page 4: ...there is a possibility of the multimeter or other equipment being damaged Warning identifies conditions or operations in which there is a possible risk of injury or death Markings on the unit Attentio...

Page 5: ...hould only use fuses of the correct types of the voltage and current ratings specified on the bottom of the meter It is strictly forbidden for repaired fuses to be used or for the fuse holders to be s...

Page 6: ...nctions it can perform are as follows Measurement of a c and d c voltages Measurement of a c and d c currents Measurement of resistance and capacitance Continuity testing Diode testing Frequency and A...

Page 7: ...e indicated Low battery voltage indication shown if the voltage from the batteries drops below the operating voltage Range overrun Highest digit flashes Display update rate Two per second for digital...

Page 8: ...uracy is given as measurement error display error and applies at 23 C 5 C and less than 80 RH Measurement error is given as a percentage of the current measurement Display error D is given in units eq...

Page 9: ...5D 50 to 60Hz 1 5 5D 50 to 60Hz 40V 10 V 400V 100mV 600V 1V Input impedance 10M in parallel with less than 100pF A c voltage conversion Mean measured r m s value displayed 3 3 3 D c current Ad c Range...

Page 10: ...Overload protection mA jack 1A 415V 32 x 6 35mm quick acting fuse A input terminal 10A 415V 32 x 6 35mm quick acting fuse A c current conversion Mean measured r m s value displayed 3 3 5 Resistance Ra...

Page 11: ...threshold Approx 40 Continuity indication 2kHz tone Input protection 600Vor 600Vrms Diode testing Measuring current 0 6mA Open circuit voltage Approx 3V Input protection 600V or 600Vrms Frequency meas...

Page 12: ...frequency and ADP measurement 5 mA input terminal Input for milliampere current measurement 6 A input terminal Input for current measurement The meter can measure currents of up to 20A but the time i...

Page 13: ...ppears on the display is 15 01 10 HOLD button Except in the MIN MAX mode this button is used to switch the data hold mode on and off When the hold mode is on appears on the display and the measurement...

Page 14: ...switches itself off automatically but it is when the rotary switch is turned to Off 14 Recall button This button can be used to recall a stored measurement to the display This is indicated by appeari...

Page 15: ...14 Figure 1 1 7 8 9 10 14 13 12 11 2 3 4 5 6...

Page 16: ...ns should be used 5 1 Preparatory steps and directions to be followed 1 After you switch the meter on wait for 30 seconds before you make the first measurement 2 You must set the desired function with...

Page 17: ...ichever lower range you then find to be required 3 Apply the probes to the circuit to the measured 5 4 Measuring resistance 1 Plug the black lead into the COM input terminal and the red lead into the...

Page 18: ...etween 0 500 and 0 900V With a faulty diode 000 short circuit or a reading of approx 3 2V open circuit will be shown 4 When tested in the opposite direction blocking direction a reading of approx 3 2V...

Page 19: ...given below 1 Remove the probes from the item from which measurements are being taken and switch the meter off 2 Unplug the leads from the jacks 3 Lay the meter front face down on a work surface which...

Page 20: ...19 Fig 2 Changing batteries Bottom half of case Top half of case 1 5V battery Battery holder...

Page 21: ...Make sure that the fuse is centered longitudinally in the fuse holder 5 Make sure that the bar of the rotary switch in the top half of the case and the rotary switch on the printed circuit board are b...

Page 22: ...21 Fig 3 Changing fuses Top half of case Bottom half of case 10A 415V fuse 1A 415V fuse Fuse holder...

Page 23: ...n experienced person who is fully aware of the risks involved If ever there is any danger that the meter is no longer safe to use no more measurements should be made with it and it should be safeguard...

Page 24: ...3 9 Using the probe holders To work one handed clip one of the probes into a probe holder To store the probes safely wind the leads around the rubber holster and clip the probes into the probe holders...

Page 25: ...24 10 Using the stand and the rubber holster Using the stand as a tilt bail for easier reading Hinging out the hook at the top to hang the meter on an electrical box door...

Page 26: ...25 11 Using the rubber holster Meter in rubber holster with rear face facing out Meter in rubber holster hung from a hook on a wall...

Page 27: ...nited Kingdom Japan West Tower 12th Floor Yokohama Business Park 134 Godocho Hodogaya Yokohama Kanagawa 240 0005 Japan USA 7410 Pebble Drive Fort Worth Texas 76118 6961 Canada 1701 Woodward Drive Ste...

Reviews: