10
3.3.6 Capacitance
Range
Resolution
Accuracy
Overload protection
4nF
1pF
±
(1% + 40D)
600Vd.c. or
600V rms
40nF
400nF
4µF
±
(1% + 4D)
40µF
10nF
±
(1% + 4D) < 20µF
±
(5% + 8D) > 20µF
10pF
100pF
1nF
Continuity testing:
Indication threshold :
Approx. 40
Ω
Continuity indication :
2kHz tone
Input protection :
600Vor 600Vrms
Diode testing:
Measuring current :
0.6mA
Open circuit voltage :
Approx. 3V
Input protection :
600V or 600Vrms
Frequency measurement:
Ranges :
100Hz, 1kHz, 10kHz, 100kHz, 10MHz
Resolution :
0.01Hz on 100Hz range
Accuracy :
±(0.1% + 4D)
Sensitivity :
40mVrms from 1Hz to 20kHz 400mVrms from 20kHz to 1MHz
Input protection :
600Vd.c. or 600Vrms