12
Basic parameters setting
Basic
The factory default setting of the camera is
1 (address), 9600bps, VISCA protocol,
1080p25 for tracking camera and full-view
camera.
Position Calibration
Adjust the lecturer’s position in the video
when he/she is not in the center of image.
Warning:
The position has been adjusted to
the best value before leaving the factory, do
not change it until it is necessary.
Adjust Head Height
User can adjust the head height in the view.
Debug
Enable and disable display current status of
face detection of tracking camera and
motion detection of full-view camera.
Zone Setting
Recommended to set the platform or podium
as priority zone, the camera will detect object
from this zone to start tracking accordingly.
Set other interference sources (like projector,
digital whiteboard, TV screen and etc) near
the platform or podium as blocking zones so
the camera will not track these sources. The
blocking zones must be inside the priority
zone; otherwise, they will not be blocked.
The camera’s tracking range can cover the
whole classroom, so the platform zone is
defined as a priority tracking zone.
Usually set the top edge of the blackboard
as the top boundary of the platform zone (at
least higher than the lecturer's head), and
the bottom boundary is higher than
students' head sitting in the first row.