Manufacturer of Quality Air Conditioning and Heating Products • www.islandaire.com • sales@islandaire.com • (800)-886-2759
37
Control panel
Use the control panel to power on/off, select mode, select
fan speed, and adjust the set temperature.
Power Control
The ON/OFF button turns the unit on and off.
Auto restart Feature
To prevent multiple units from powering
up simultaneously after a power outage,
there will be a random 5 to 15 second delay
before the unit turns on after power has been
restored.
memory recall Feature
The control board utilizes “non-volatile”
memory; computer memory that can retain
stored information when not powered. This
allows all control settings to be saved and
recalled after a power failure or if power is
disconnected while servicing the unit.
compressor short cycle protection
Built-in three minute timing delay: If cycle is
interrupted, the compressor will not restart
for three minutes. On all initial power ups
there is a one-time, 3 minute time delay
before the unit will function.
Digital Control Panel
AUTO
Figure 41
Digital Control Panel
Display
The display shows the room temperature (return air
temperature) when the unit is in operation. When
the temperature is adjusted by pressing the “Warm” or
“Cool” buttons the display briefly shows the set tempera-
ture, for three seconds and then defaults back to room
temperature.
Mode Control - Cool,
Fan, and Heat
A light will indicate which mode is currently being
utilized.
Cool Mode:
The unit will circulate and cool the air.
Fan Mode:
The unit will only circulate the air.
Heat Mode:
The unit will circulate and heat the air.
heater safety Feature
When heater is powered off, fan will
automatically stay on and run for 60 seconds to
ensure the removal of residual heat.