Chapter 3 Test Mode
3-17
AC-4000H Service Manual No. 085-7323-08
3.9
Peel Sensor Check
PEEL SENSOR CHECK
Press the [
↓
] key to increment a menu, or enter a desired menu number followed by the [
↓
] key.
kg
MASS
R/kg
R
AMOUNT
2''.5'0514%*'%-='06'4?
2''.5'0514%*'%-='06'4?
PEEL SENSOR [Output value is checked]
kg
MASS
R/kg
R
AMOUNT
2''.5'0514
2''.5'0514
•
Sensor value display
[255]: Peel sensor resistance
[186]: Peel sensor output value (Label + Backing paper)
[255]: Peel sensor resistance
[0] : Peel sensor output value (Backing paper only)
•
Output from the peel sensor is displayed with a value after passing through the A/D converter.
•
Setting range: 0 t o 255
•
Input method: Key in 0 to 255, and press the ENTER key to store.
•
Press the END key to return to the test mode menu screen.